Papers with Code 아카이브

MRI Reconstruction

태스크의 하위 분류와 논문·코드·평가·기법·데이터셋을 탐색하세요.

하위 태스크
2
평가표
6
보존된 평가 기록
15

In its most basic form, MRI reconstruction consists in retrieving a complex-valued image from its under-sampled Fourier coefficients. Besides, it can be addressed as a encoder-decoder task, in which the normative model in the latent space will only capture the relevant information without noise or corruptions. Then, we decode the latent space in order to have a reconstructed MRI.

데이터셋

출처에 같은 태스크 이름으로 연결된 데이터셋입니다. 동명 태스크가 포함될 수 있으므로, 비교할 때는 평가 결과의 조건도 확인하세요.

fastMRI

The fastMRI dataset includes two types of MRI scans: knee MRIs and the brain (neuro) MRIs, and containing training, validation, and masked test sets. The deidentified imaging dataset provided by NYU Langone comprises raw k-space data in several sub-dataset groups. Curation of these data are part of an IRB approved study. Raw and DICOM data have been deidentified via conversion to the vendor-neutral ISMRMD format and the RSNA clinical trial processor, respectively. Also, each DICOM image is manually inspected for the presence of any unexpected protected health information (PHI), with spot checking of both metadata and image content. Knee MRI: Data from more than 1,500 fully sampled knee MRIs obtained on 3 and 1.5 Tesla magnets and DICOM images from 10,000 clinical knee MRIs also obtained at 3 or 1.5 Tesla. The raw dataset includes coronal proton density-weighted images with and without fat suppression. The DICOM dataset contains coronal proton density-weighted with and without fat suppression, axial proton density-weighted with fat suppression, sagittal proton density, and sagittal T2-weighted with fat suppression. Brain MRI: Data from 6,970 fully sampled brain MRIs obtained on 3 and 1.5 Tesla magnets. The raw dataset includes axial T1 weighted, T2 weighted and FLAIR images. Some of the T1 weighted acquisitions included admissions of contrast agent. Source: https://fastmri.med.nyu.edu/ Image Source: https://fastmri.med.nyu.edu/

IXI

IXI Dataset is a collection of 600 MR brain images from normal, healthy subjects. The MR image acquisition protocol for each subject includes: * T1, T2 and PD-weighted images * MRA images * Diffusion-weighted images (15 directions) The data has been collected at three different hospitals in London: * Hammersmith Hospital using a Philips 3T system (details of scanner parameters) * Guy’s Hospital using a Philips 1.5T system (details of scanner parameters) * Institute of Psychiatry using a GE 1.5T system (details of the scan parameters not available at the moment) The data has been collected as part of the project: * IXI – Information eXtraction from Images (EPSRC GR/S21533/02) The images in NIFTI format can be downloaded from here: This data is made available under the Creative Commons CC BY-SA 3.0 license. If you use the IXI data please acknowledge the source of the IXI data.

SKM-TEA

The SKM-TEA dataset pairs raw quantitative knee MRI (qMRI) data, image data, and dense labels of tissues and pathology for end-to-end exploration and evaluation of the MR imaging pipeline. This 1.6TB dataset consists of raw-data measurements of ~25,000 slices (155 patients) of anonymized patient knee MRI scans, the corresponding scanner-generated DICOM images, manual segmentations of four tissues, and bounding box annotations for sixteen clinically relevant pathologies. ## Challenge Tracks DICOM Track: The DICOM benchmarking track uses scanner-generated DICOM images as the input for image segmentation and detection tasks. Raw Data Track: The Raw Data benchmarking track uses raw MRI data (i.e. k-space) as the input for image reconstruction, segmentation and detection tasks.

M4Raw

Recently, low-field magnetic resonance imaging (MRI) has gained renewed interest to promote MRI accessibility and affordability worldwide. The presented M4Raw dataset aims to facilitate methodology development and reproducible research in this field. The dataset comprises multi-channel brain k-space data collected from 183 healthy volunteers using a 0.3 Tesla whole-body MRI system, and includes T1-weighted, T2-weighted, and fluid attenuated inversion recovery (FLAIR) images with in-plane resolution of ~1.2 mm and through-plane resolution of 5 mm. Importantly, each contrast contains multiple repetitions, which can be used individually or to form multi-repetition averaged images. After excluding motion-corrupted data, the partitioned training and validation subsets contain 1024 and 240 volumes, respectively. To demonstrate the potential utility of this dataset, we trained deep learning models for image denoising and parallel imaging tasks and compared their performance with traditional reconstruction methods. This M4Raw dataset will be valuable for the development of advanced data-driven methods specifically for low-field MRI. It can also serve as a benchmark dataset for general MRI reconstruction algorithms. Reference: Lyu, M., Mei, L., Huang, S. et al. M4Raw: A multi-contrast, multi-repetition, multi-channel MRI k-space dataset for low-field MRI research. Sci Data 10, 264 (2023). https://doi.org/10.1038/s41597-023-02181-4

출처: Papers with Code · CC BY-SA 4.0. 아카이브 자료와 새로 수집한 논문은 별도로 관리합니다.