Papers with Code 아카이브

GLinear

태스크의 하위 분류와 논문·코드·평가·기법·데이터셋을 탐색하세요.

하위 태스크
0
평가표
19
보존된 평가 기록
19

It is a simpler model; it is not made up of any complex components, functions or blocks (like self-attention schemes, positional encoding blocks, etc.). It integrates two components: (1) a non-linear GeLU-based transformation layer to capture intricate patterns, and (2) Reversible Instance Normalization (RevIN).

  1. Due to its simple architecture, training of this model is very fast as compared to other transformer based predictors.
  2. This proposed model provides comparable performance to other state-of-the-art predictors.

데이터셋

출처에 같은 태스크 이름으로 연결된 데이터셋입니다. 동명 태스크가 포함될 수 있으므로, 비교할 때는 평가 결과의 조건도 확인하세요.

ETT

The Electricity Transformer Temperature (ETT) is a crucial indicator in the electric power long-term deployment. This dataset consists of 2 years data from two separated counties in China. To explore the granularity on the Long sequence time-series forecasting (LSTF) problem, different subsets are created, {ETTh1, ETTh2} for 1-hour-level and ETTm1 for 15-minutes-level. Each data point consists of the target value ”oil temperature” and 6 power load features. The train/val/test is 12/4/4 months. Source: https://arxiv.org/pdf/2012.07436.pdf Image Source: https://github.com/zhouhaoyi/ETDataset

Electricity

Abstract: Measurements of electric power consumption in one household with a one-minute sampling rate over a period of almost 4 years. Different electrical quantities and some sub-metering values are available. | Data Set Characteristics | Number of Instances | Area | Attribute Characteristics | Number of Attributes | Date Donated | Associated Tasks | Missing Values | | ------------------------- | ------------------- | -------- | ------------------------- | -------------------- | ------------ | ---------------------- | -------------- | | Multivariate, Time-Series | 2075259 | Physical | Real | 9 | 2012-08-30 | Regression, Clustering | Yes | ### Source: Georges Hebrail (georges.hebrail '@' edf.fr), Senior Researcher, EDF R&D, Clamart, France Alice Berard, TELECOM ParisTech Master of Engineering Internship at EDF R&D, Clamart, France ### Data Set Information: This archive contains 2075259 measurements gathered in a house located in Sceaux (7km of Paris, France) between December 2006 and November 2010 (47 months). Notes: 1. (global_active_power*1000/60 - sub_metering_1 - sub_metering_2 - sub_metering_3) represents the active energy consumed every minute (in watt hour) in the household by electrical equipment not measured in sub-meterings 1, 2 and 3. 2. The dataset contains some missing values in the measurements (nearly 1,25% of the rows). All calendar timestamps are present in the dataset but for some timestamps, the measurement values are missing: a missing value is represented by the absence of value between two consecutive semi-colon attribute separators. For instance, the dataset shows missing values on April 28, 2007. ### Attribute Information: 1. date: Date in format dd/mm/yyyy 2. time: time in format hh:mm:ss 3. global_active_power: household global minute-averaged active power (in kilowatt) 4. global_reactive_power: household global minute-averaged reactive power (in kilowatt) 5. voltage: minute-averaged voltage (in volt) 6. global_intensity: household global minute-averaged current intensity (in ampere) 7. sub_metering_1: energy sub-metering No. 1 (in watt-hour of active energy). It corresponds to the kitchen, containing mainly a dishwasher, an oven and a microwave (hot plates are not electric but gas powered). 8. sub_metering_2: energy sub-metering No. 2 (in watt-hour of active energy). It corresponds to the laundry room, containing a washing-machine, a tumble-drier, a refrigerator and a light. 9. sub_metering_3: energy sub-metering No. 3 (in watt-hour of active energy). It corresponds to an electric water-heater and an air-conditioner. ### Relevant Papers: N/A ### Citation Request: This dataset is made available under the “Creative Commons Attribution 4.0 International (CC BY 4.0)” license

ETTh1 (96)

The Electricity Transformer Temperature (ETT) is a crucial indicator in the electric power long-term deployment. This dataset consists of 2 years data from two separated counties in China. To explore the granularity on the Long sequence time-series forecasting (LSTF) problem, different subsets are created, {ETTh1, ETTh2} for 1-hour-level and ETTm1 for 15-minutes-level. Each data point consists of the target value ”oil temperature” and 6 power load features. The train/val/test is 12/4/4 months. Source: https://arxiv.org/pdf/2012.07436.pdf Image Source: https://github.com/zhouhaoyi/ETDataset

Traffic

Abstract: The task for this dataset is to forecast the spatio-temporal traffic volume based on the historical traffic volume and other features in neighboring locations. | Data Set Characteristics | Number of Instances | Area | Attribute Characteristics | Number of Attributes | Date Donated | Associated Tasks | Missing Values | | ------------------------ | ------------------- | -------- | ------------------------- | -------------------- | ------------ | ---------------- | -------------- | | Multivariate | 2101 | Computer | Real | 47 | 2020-11-17 | Regression | N/A | ### Source: Liang Zhao, liang.zhao '@' emory.edu, Emory University. ### Data Set Information: The task for this dataset is to forecast the spatio-temporal traffic volume based on the historical traffic volume and other features in neighboring locations. Specifically, the traffic volume is measured every 15 minutes at 36 sensor locations along two major highways in Northern Virginia/Washington D.C. capital region. The 47 features include: 1) the historical sequence of traffic volume sensed during the 10 most recent sample points (10 features), 2) week day (7 features), 3) hour of day (24 features), 4) road direction (4 features), 5) number of lanes (1 feature), and 6) name of the road (1 feature). The goal is to predict the traffic volume 15 minutes into the future for all sensor locations. With a given road network, we know the spatial connectivity between sensor locations. For the detailed data information, please refer to the file README.docx. ### Attribute Information: The 47 features include: (1) the historical sequence of traffic volume sensed during the 10 most recent sample points (10 features), (2) week day (7 features), (3) hour of day (24 features), (4) road direction (4 features), (5) number of lanes (1 feature), and (6) name of the road (1 feature). ### Relevant Papers: Liang Zhao, Olga Gkountouna, and Dieter Pfoser. 2019. Spatial Auto-regressive Dependency Interpretable Learning Based on Spatial Topological Constraints. ACM Trans. Spatial Algorithms Syst. 5, 3, Article 19 (August 2019), 28 pages. DOI:[Web Link] ### Citation Request: To use these datasets, please cite the papers: Liang Zhao, Olga Gkountouna, and Dieter Pfoser. 2019. Spatial Auto-regressive Dependency Interpretable Learning Based on Spatial Topological Constraints. ACM Trans. Spatial Algorithms Syst. 5, 3, Article 19 (August 2019), 28 pages. DOI:[Web Link]

ETTh1 (192)

The Electricity Transformer Temperature (ETT) is a crucial indicator in the electric power long-term deployment. This dataset consists of 2 years data from two separated counties in China. To explore the granularity on the Long sequence time-series forecasting (LSTF) problem, different subsets are created, {ETTh1, ETTh2} for 1-hour-level and ETTm1 for 15-minutes-level. Each data point consists of the target value ”oil temperature” and 6 power load features. The train/val/test is 12/4/4 months. Source: https://arxiv.org/pdf/2012.07436.pdf Image Source: https://github.com/zhouhaoyi/ETDataset

출처: Papers with Code · CC BY-SA 4.0. 아카이브 자료와 새로 수집한 논문은 별도로 관리합니다.