Papers with Code 아카이브

EMG Gesture Recognition

태스크의 하위 분류와 논문·코드·평가·기법·데이터셋을 탐색하세요.

하위 태스크
0
평가표
0
보존된 평가 기록
0

Electromyographic Gesture Recognition

데이터셋

출처에 같은 태스크 이름으로 연결된 데이터셋입니다. 동명 태스크가 포함될 수 있으므로, 비교할 때는 평가 결과의 조건도 확인하세요.

NinaPro DB2

The second Ninapro database includes 40 intact subjects and it is thoroughly described in the paper: "Manfredo Atzori, Arjan Gijsberts, Claudio Castellini, Barbara Caputo, Anne-Gabrielle Mittaz Hager, Simone Elsig, Giorgio Giatsidis, Franco Bassetto & Henning Müller. Electromyography data for non-invasive naturally-controlled robotic hand prostheses. Scientific Data, 2014" (http://www.nature.com/articles/sdata201453). Please, cite this paper for any work related to the Ninapro database. Please, use also the paper by Gijsberts et al., 2014 (http://publications.hevs.ch/index.php/publications/show/1629) for more information about the database.

Ninapro DB5

The 5th Ninapro database includes 10 intact subjects recorded with two Thalmic Myo (https://www.myo.com/) armbands. The database can be used to test the Myo armbands separately as well. The 5th Ninapro database is thoroughly described in the paper: "Stefano Pizzolato, Luca Tagliapietra, Matteo Cognolato, Monica Reggiani, Henning Müller, Manfredo Atzori, Comparison of six electromyography acquisition setups on hand movement classification tasks, PLOS One, 2017" ### Acquisition Protocol The subjects have to repeat several movements represented by movies that are shown on the screen of a laptop. The experiment is divided in three exercises: 1. Basic movements of the fingers 2. Isometric, isotonic hand configurations and basic wrist movements 3. Grasping and functional movements During the acquisition, the subjects were asked to repeat the movements with the right hand. Each movement repetition lasted 5 seconds and was followed by 3 seconds of rest. The protocol includes 6 repetitions of 52 different movements (plus rest) performed by 10 intact subjects. The movements were selected from the hand taxonomy as well as from hand robotics literature. ### Acquisition Setup The muscular activity is gathered using 2 Thalmic Myo armbands. The database can be used to test the Myo armbands separately as well. The subjects in this database wore two Myo armbands one next to the other, including 16 active single–differential wireless electrodes. The top Myo armband is placed closed to the elbow with the first sensor placed on the radio humeral joint, as in the standard Ninapro configuration for the equally spaced electrodes; the second Myo armband is placed just after the first, nearer to the hand, tilted of 22.5 degrees. This configuration provides an extended uniform muscle mapping at an extremely affordable cost. The Myo sensors do not require the arm to be shaved and after few minutes the armband tighten very firmly to the arm of the subject. The sEMG signals are sampled at a rate of 200 Hz.

출처: Papers with Code · CC BY-SA 4.0. 아카이브 자료와 새로 수집한 논문은 별도로 관리합니다.