arXiv:2404.15352v3eess.SP

TransfoRhythm: A Transformer Architecture Conductive to Blood Pressure Estimation via Solo PPG Signal Capturing

Recent statistics indicate that approximately 1.3 billion individuals worldwide suffer from hypertension, a leading cause of premature death globally. Blood Pressure (BP) serves as a critical health indicator for accurate and timely diagnosis and/or treatment of hypertension. Traditional BP measurement methods rely on cuff-based approaches, which lack real-time, continuous, and reliable BP estimates, crucial for the timely diagnosis/treatment of hypertension. Driven by recent advancements in Artificial Intelligence (AI) and Deep Neural Networks (DNNs), there has been a surge of interest in developing data-driven and cuff-less BP estimation solutions. In this context, current literature predominantly focuses on coupling Electrocardiography (ECG) and Photoplethysmography (PPG) sensors, though this approach is constrained by reliance on multiple sensor types. An alternative, utilizing standalone PPG signals, presents challenges due to the absence of auxiliary sensors (ECG), requiring the use of morphological features while addressing motion artifacts and high-frequency noise. To address these issues, the paper introduces the TransfoRhythm framework, a Transformer-based DNN architecture built upon the recently released physiological database, MIMIC-IV. Leveraging the Multi-Head Attention (MHA) mechanism, TransfoRhythm identifies dependencies and similarities across data segments, forming a robust framework for cuff-less BP estimation solely using PPG signals. To our knowledge, this paper represents the first study to apply the MIMIC IV dataset for cuff-less BP estimation. TransfoRhythm achieves highly accurate results with a Root Mean Square Error (RMSE) of [2.21, 1.84] and a Mean Absolute Error (MAE) of [1.37, 1.06] for systolic and diastolic blood pressures, respectively.

arXiv:2505.04172

A Dataset and Toolkit for Multiparameter Cardiovascular Physiology Sensing on Rings

Smart rings offer a convenient way to continuously and unobtrusively monitor cardiovascular physiological signals. However, a gap remains between the ring hardware and reliable methods for estimating cardiovascular parameters, partly due to the lack of publicly available datasets and standardized analysis tools. In this work, we present $\tau$-Ring, the first open-source ring-based dataset designed for cardiovascular physiological sensing. The dataset comprises photoplethysmography signals (infrared and red channels) and 3-axis accelerometer data collected from two rings (reflective and transmissive optical paths), with 28.21 hours of raw data from 34 subjects across seven activities. $\tau$-Ring encompasses both stationary and motion scenarios, as well as stimulus-evoked abnormal physiological states, annotated with four ground-truth labels: heart rate, respiratory rate, oxygen saturation, and blood pressure. Using our proposed RingTool toolkit, we evaluated three widely-used physics-based methods and four cutting-edge deep learning approaches. Our results show superior performance compared to commercial rings, achieving best MAE values of 5.18 BPM for heart rate, 2.98 BPM for respiratory rate, 3.22\% for oxygen saturation, and 13.33/7.56 mmHg for systolic/diastolic blood pressure estimation. The open-sourced dataset and toolkit aim to foster further research and community-driven advances in ring-based cardiovascular health sensing.

arXiv:2502.19167공식 코드 · Papers with Code

Generalizable deep learning for photoplethysmography-based blood pressure estimation -- A Benchmarking Study

Photoplethysmography (PPG)-based blood pressure (BP) estimation represents a promising alternative to cuff-based BP measurements. Recently, an increasing number of deep learning models have been proposed to infer BP from the raw PPG waveform. However, these models have been predominantly evaluated on in-distribution test sets, which immediately raises the question of the generalizability of these models to external datasets. To investigate this question, we trained five deep learning models on the recently released PulseDB dataset, provided in-distribution benchmarking results on this dataset, and then assessed out-of-distribution performance on several external datasets. The best model (XResNet1d101) achieved in-distribution MAEs of 9.4 and 6.0 mmHg for systolic and diastolic BP respectively on PulseDB (with subject-specific calibration), and 14.0 and 8.5 mmHg respectively without calibration. Equivalent MAEs on external test datasets without calibration ranged from 15.0 to 25.1 mmHg (SBP) and 7.0 to 10.4 mmHg (DBP). Our results indicate that the performance is strongly influenced by the differences in BP distributions between datasets. We investigated a simple way of improving performance through sample-based domain adaptation and put forward recommendations for training models with good generalization properties. With this work, we hope to educate more researchers for the importance and challenges of out-of-distribution generalization.

arXiv:2502.17460

Finetuning and Quantization of EEG-Based Foundational BioSignal Models on ECG and PPG Data for Blood Pressure Estimation

Blood pressure (BP) is a key indicator of cardiovascular health. As hypertension remains a global cause of morbidity and mortality, accurate, continuous, and non-invasive BP monitoring is therefore of paramount importance. Photoplethysmography (PPG) and electrocardiography (ECG) can potentially enable continuous BP monitoring, yet training accurate and robust machine learning (ML) models remains challenging due to variability in data quality and patient-specific factors. Recently, multiple research groups explored Electroencephalographic (EEG)--based foundation models and demonstrated their exceptional ability to learn rich temporal resolution. Considering the morphological similarities between different biosignals, the question arises of whether a model pre-trained on one modality can effectively be exploited to improve the accuracy of a different signal type. In this work, we take an initial step towards generalized biosignal foundation models by investigating whether model representations learned from abundant EEG data can effectively be transferred to ECG/PPG data solely with fine-tuning, without the need for large-scale additional pre-training, for the BP estimation task. Evaluations on the MIMIC-III and VitalDB datasets demonstrate that our approach achieves near state-of-the-art accuracy for diastolic BP (mean absolute error of 1.57 mmHg) and surpasses by 1.5x the accuracy of prior works for systolic BP (mean absolute error 2.72 mmHg). Additionally, we perform dynamic INT8 quantization, reducing the smallest model size by over 3.5x (from 13.73 MB down to 3.83 MB) while preserving performance, thereby enabling unobtrusive, real-time BP monitoring on resource-constrained wearable devices.

arXiv:2409.07485

Optimization and Deployment of Deep Neural Networks for PPG-based Blood Pressure Estimation Targeting Low-power Wearables

PPG-based Blood Pressure (BP) estimation is a challenging biosignal processing task for low-power devices such as wearables. State-of-the-art Deep Neural Networks (DNNs) trained for this task implement either a PPG-to-BP signal-to-signal reconstruction or a scalar BP value regression and have been shown to outperform classic methods on the largest and most complex public datasets. However, these models often require excessive parameter storage or computational effort for wearable deployment, exceeding the available memory or incurring too high latency and energy consumption. In this work, we describe a fully-automated DNN design pipeline, encompassing HW-aware Neural Architecture Search (NAS) and Quantization, thanks to which we derive accurate yet lightweight models, that can be deployed on an ultra-low-power multicore System-on-Chip (SoC), GAP8. Starting from both regression and signal-to-signal state-of-the-art models on four public datasets, we obtain optimized versions that achieve up to 4.99% lower error or 73.36% lower size at iso-error. Noteworthy, while the most accurate SoA network on the largest dataset can not fit the GAP8 memory, all our optimized models can; our most accurate DNN consumes as little as 0.37 mJ while reaching the lowest MAE of 8.08 on Diastolic BP estimation.

arXiv:2408.08488공식 코드 · Papers with Code

PITN: Physics-Informed Temporal Networks for Cuffless Blood Pressure Estimation

Monitoring blood pressure with non-invasive sensors has gained popularity for providing comfortable user experiences, one of which is a significant function of smart wearables. Although providing a comfortable user experience, such methods are suffering from the demand for a significant amount of realistic data to train an individual model for each subject, especially considering the invasive or obtrusive BP ground-truth measurements. To tackle this challenge, we introduce a novel physics-informed temporal network~(PITN) with adversarial contrastive learning to enable precise BP estimation with very limited data. Specifically, we first enhance the physics-informed neural network~(PINN) with the temporal block for investigating BP dynamics' multi-periodicity for personal cardiovascular cycle modeling and temporal variation. We then employ adversarial training to generate extra physiological time series data, improving PITN's robustness in the face of sparse subject-specific training data. Furthermore, we utilize contrastive learning to capture the discriminative variations of cardiovascular physiologic phenomena. This approach aggregates physiological signals with similar blood pressure values in latent space while separating clusters of samples with dissimilar blood pressure values. Experiments on three widely-adopted datasets with different modailties (\emph{i.e.,} bioimpedance, PPG, millimeter-wave) demonstrate the superiority and effectiveness of the proposed methods over previous state-of-the-art approaches. The code is available at~\url{https://github.com/Zest86/ACL-PITN}.

arXiv:2406.08930공식 코드 · Papers with Code

Efficient Multi-View Fusion and Flexible Adaptation to View Missing in Cardiovascular System Signals

The progression of deep learning and the widespread adoption of sensors have facilitated automatic multi-view fusion (MVF) about the cardiovascular system (CVS) signals. However, prevalent MVF model architecture often amalgamates CVS signals from the same temporal step but different views into a unified representation, disregarding the asynchronous nature of cardiovascular events and the inherent heterogeneity across views, leading to catastrophic view confusion. Efficient training strategies specifically tailored for MVF models to attain comprehensive representations need simultaneous consideration. Crucially, real-world data frequently arrives with incomplete views, an aspect rarely noticed by researchers. Thus, the View-Centric Transformer (VCT) and Multitask Masked Autoencoder (M2AE) are specifically designed to emphasize the centrality of each view and harness unlabeled data to achieve superior fused representations. Additionally, we systematically define the missing-view problem for the first time and introduce prompt techniques to aid pretrained MVF models in flexibly adapting to various missing-view scenarios. Rigorous experiments involving atrial fibrillation detection, blood pressure estimation, and sleep staging-typical health monitoring tasks-demonstrate the remarkable advantage of our method in MVF compared to prevailing methodologies. Notably, the prompt technique requires finetuning less than 3% of the entire model's data, substantially fortifying the model's resilience to view missing while circumventing the need for complete retraining. The results demonstrate the effectiveness of our approaches, highlighting their potential for practical applications in cardiovascular health monitoring. Codes and models are released at URL.

arXiv:2404.16049

Exploring the limitations of blood pressure estimation using the photoplethysmography signal

Hypertension, a leading contributor to cardiovascular morbidity, underscores the need for accurate and continuous blood pressure (BP) monitoring. Photoplethysmography (PPG) presents a promising approach to this end. However, the precision of BP estimates derived from PPG signals has been the subject of ongoing debate, necessitating a comprehensive evaluation of their effectiveness and constraints. We developed a calibration-based Siamese ResNet model for BP estimation, using a signal input paired with a reference BP reading. We compared the use of normalized PPG (N-PPG) against the normalized Invasive Arterial Blood Pressure (N-IABP) signals as input. The N-IABP signals do not directly present systolic and diastolic values but theoretically provide a more accurate BP measure than PPG signals since it is a direct pressure sensor inside the body. Our strategy establishes a critical benchmark for PPG performance, realistically calibrating expectations for PPG's BP estimation capabilities. Nonetheless, we compared the performance of our models using different signal-filtering conditions to evaluate the impact of filtering on the results. We evaluated our method using the AAMI and the BHS standards employing the VitalDB dataset. The N-IABP signals meet with AAMI standards for both Systolic Blood Pressure (SBP) and Diastolic Blood Pressure (DBP), with errors of 1.29+-6.33mmHg for systolic pressure and 1.17+-5.78mmHg for systolic and diastolic pressure respectively for the raw N-IABP signal. In contrast, N-PPG signals, in their best setup, exhibited inferior performance than N-IABP, presenting 1.49+-11.82mmHg and 0.89+-7.27mmHg for systolic and diastolic pressure respectively. Our findings highlight the potential and limitations of employing PPG for BP estimation, showing that these signals contain information correlated to BP but may not be sufficient for predicting it accurately.

arXiv:2402.18886

BP-DeepONet: A new method for cuffless blood pressure estimation using the physcis-informed DeepONet

Cardiovascular diseases (CVDs) are the leading cause of death worldwide, with blood pressure serving as a crucial indicator. Arterial blood pressure (ABP) waveforms provide continuous pressure measurements throughout the cardiac cycle and offer valuable diagnostic insights. Consequently, there is a significant demand for non-invasive and cuff-less methods to measure ABP waveforms continuously. Accurate prediction of ABP waveforms can also improve the estimation of mean blood pressure, an essential cardiovascular health characteristic. This study proposes a novel framework based on the physics-informed DeepONet approach to predict ABP waveforms. Unlike previous methods, our approach requires the predicted ABP waveforms to satisfy the Navier-Stokes equation with a time-periodic condition and a Windkessel boundary condition. Notably, our framework is the first to predict ABP waveforms continuously, both with location and time, within the part of the artery that is being simulated. Furthermore, our method only requires ground truth data at the outlet boundary and can handle periodic conditions with varying periods. Incorporating the Windkessel boundary condition in our solution allows for generating natural physical reflection waves, which closely resemble measurements observed in real-world cases. Moreover, accurately estimating the hyper-parameters in the Navier-Stokes equation for our simulations poses a significant challenge. To overcome this obstacle, we introduce the concept of meta-learning, enabling the neural networks to learn these parameters during the training process.

arXiv:2402.02224

MSPM: A Multi-Site Physiological Monitoring Dataset for Remote Pulse, Respiration, and Blood Pressure Estimation

Visible-light cameras can capture subtle physiological biomarkers without physical contact with the subject. We present the Multi-Site Physiological Monitoring (MSPM) dataset, which is the first dataset collected to support the study of simultaneous camera-based vital signs estimation from multiple locations on the body. MSPM enables research on remote photoplethysmography (rPPG), respiration rate, and pulse transit time (PTT); it contains ground-truth measurements of pulse oximetry (at multiple body locations) and blood pressure using contacting sensors. We provide thorough experiments demonstrating the suitability of MSPM to support research on rPPG, respiration rate, and PTT. Cross-dataset rPPG experiments reveal that MSPM is a challenging yet high quality dataset, with intra-dataset pulse rate mean absolute error (MAE) below 4 beats per minute (BPM), and cross-dataset pulse rate MAE below 2 BPM in certain cases. Respiration experiments find a MAE of 1.09 breaths per minute by extracting motion features from the chest. PTT experiments find that across the pairs of different body sites, there is high correlation between remote PTT and contact-measured PTT, which facilitates the possibility for future camera-based PTT research.

논문 ID: publication/3737276

RGB Camera-Based Blood Pressure Measurement Using U-Net Basic Generative Model

Blood pressure is a fundamental health metric widely employed to predict cardiac diseases and monitor overall well-being. However, conventional blood pressure measurement methods, such as the cuff method, necessitate additional equipment and can be inconvenient for regular use. This study aimed to develop a novel approach to blood pressure measurement using only an RGB camera, which promises enhanced convenience and accuracy. We employed the U-Net Basic generative model to achieve our objectives. Through rigorous experimentation and data analysis, our approach demonstrated promising results, attaining BHS (British Hypertension Society) baseline performance with grade A accuracy for diastolic blood pressure (DBP) and grade C accuracy for systolic blood pressure (SBP). The mean absolute error (MAE) achieved for DBP was 4.43 mmHg, and for SBP, it was 6.9 mmHg. Our findings indicate that blood pressure measurement using an RGB camera shows significant potential and may be utilized as an alternative or supplementary method for blood pressure monitoring. The convenience of using a commonly available RGB camera without additional specialized equipment can empower individuals to track their blood pressure regularly and proactively predict potential heart-related issues.

arXiv:2311.15098

Speech-Based Blood Pressure Estimation with Enhanced Optimization and Incremental Clustering

Blood Pressure (BP) estimation plays a pivotal role in diagnosing various health conditions, highlighting the need for innovative approaches to overcome conventional measurement challenges. Leveraging machine learning and speech signals, this study investigates accurate BP estimation with a focus on preprocessing, feature extraction, and real-time applications. An advanced clustering-based strategy, incorporating the k-means algorithm and the proposed Fact-Finding Instructor optimization algorithm, is introduced to enhance accuracy. The combined outcome of these clustering techniques enables robust BP estimation. Moreover, extending beyond these insights, this study delves into the dynamic realm of contemporary digital content consumption. Platforms like YouTube have emerged as influential spaces, presenting an array of videos that evoke diverse emotions. From heartwarming and amusing content to intense narratives, YouTube captures a spectrum of human experiences, influencing information access and emotional engagement. Within this context, this research investigates the interplay between YouTube videos and physiological responses, particularly Blood Pressure (BP) levels. By integrating advanced BP estimation techniques with the emotional dimensions of YouTube videos, this study enriches our understanding of how modern media environments intersect with health implications.

arXiv:2311.10996공식 코드 · Papers with Code

BrainZ-BP: A Non-invasive Cuff-less Blood Pressure Estimation Approach Leveraging Brain Bio-impedance and Electrocardiogram

Accurate and continuous blood pressure (BP) monitoring is essential to the early prevention of cardiovascular diseases. Non-invasive and cuff-less BP estimation algorithm has gained much attention in recent years. Previous studies have demonstrated that brain bio-impedance (BIOZ) is a promising technique for non-invasive intracranial pressure (ICP) monitoring. Clinically, treatment for patients with traumatic brain injuries (TBI) requires monitoring the ICP and BP of patients simultaneously. Estimating BP by brain BIOZ directly can reduce the number of sensors attached to the patients, thus improving their comfort. To address the issues, in this study, we explore the feasibility of leveraging brain BIOZ for BP estimation and propose a novel cuff-less BP estimation approach called BrainZ-BP. Two electrodes are placed on the forehead and occipital bone of the head in the anterior-posterior direction for brain BIOZ measurement. Various features including pulse transit time and morphological features of brain BIOZ are extracted and fed into four regression models for BP estimation. Results show that the mean absolute error, root mean square error, and correlation coefficient of random forest regression model are 2.17 mmHg, 3.91 mmHg, and 0.90 for systolic pressure estimation, and are 1.71 mmHg, 3.02 mmHg, and 0.89 for diastolic pressure estimation. The presented BrainZ-BP can be applied in the brain BIOZ-based ICP monitoring scenario to monitor BP simultaneously.

arXiv:2308.13568공식 코드 · Papers with Code

Region-Disentangled Diffusion Model for High-Fidelity PPG-to-ECG Translation

The high prevalence of cardiovascular diseases (CVDs) calls for accessible and cost-effective continuous cardiac monitoring tools. Despite Electrocardiography (ECG) being the gold standard, continuous monitoring remains a challenge, leading to the exploration of Photoplethysmography (PPG), a promising but more basic alternative available in consumer wearables. This notion has recently spurred interest in translating PPG to ECG signals. In this work, we introduce Region-Disentangled Diffusion Model (RDDM), a novel diffusion model designed to capture the complex temporal dynamics of ECG. Traditional Diffusion models like Denoising Diffusion Probabilistic Models (DDPM) face challenges in capturing such nuances due to the indiscriminate noise addition process across the entire signal. Our proposed RDDM overcomes such limitations by incorporating a novel forward process that selectively adds noise to specific regions of interest (ROI) such as QRS complex in ECG signals, and a reverse process that disentangles the denoising of ROI and non-ROI regions. Quantitative experiments demonstrate that RDDM can generate high-fidelity ECG from PPG in as few as 10 diffusion steps, making it highly effective and computationally efficient. Additionally, to rigorously validate the usefulness of the generated ECG signals, we introduce CardioBench, a comprehensive evaluation benchmark for a variety of cardiac-related tasks including heart rate and blood pressure estimation, stress classification, and the detection of atrial fibrillation and diabetes. Our thorough experiments show that RDDM achieves state-of-the-art performance on CardioBench. To the best of our knowledge, RDDM is the first diffusion model for cross-modal signal-to-signal translation in the bio-signal domain.

arXiv:2308.02425공식 코드 · Papers with Code

Hypertension Detection From High-Dimensional Representation of Photoplethysmogram Signals

Hypertension is commonly referred to as the "silent killer", since it can lead to severe health complications without any visible symptoms. Early detection of hypertension is crucial in preventing significant health issues. Although some studies suggest a relationship between blood pressure and certain vital signals, such as Photoplethysmogram (PPG), reliable generalization of the proposed blood pressure estimation methods is not yet guaranteed. This lack of certainty has resulted in some studies doubting the existence of such relationships, or considering them weak and limited to heart rate and blood pressure. In this paper, a high-dimensional representation technique based on random convolution kernels is proposed for hypertension detection using PPG signals. The results show that this relationship extends beyond heart rate and blood pressure, demonstrating the feasibility of hypertension detection with generalization. Additionally, the utilized transform using convolution kernels, as an end-to-end time-series feature extractor, outperforms the methods proposed in the previous studies and state-of-the-art deep learning models.

arXiv:2304.14916

"Can't Take the Pressure?": Examining the Challenges of Blood Pressure Estimation via Pulse Wave Analysis

The use of observed wearable sensor data (e.g., photoplethysmograms [PPG]) to infer health measures (e.g., glucose level or blood pressure) is a very active area of research. Such technology can have a significant impact on health screening, chronic disease management and remote monitoring. A common approach is to collect sensor data and corresponding labels from a clinical grade device (e.g., blood pressure cuff), and train deep learning models to map one to the other. Although well intentioned, this approach often ignores a principled analysis of whether the input sensor data has enough information to predict the desired metric. We analyze the task of predicting blood pressure from PPG pulse wave analysis. Our review of the prior work reveals that many papers fall prey data leakage, and unrealistic constraints on the task and the preprocessing steps. We propose a set of tools to help determine if the input signal in question (e.g., PPG) is indeed a good predictor of the desired label (e.g., blood pressure). Using our proposed tools, we have found that blood pressure prediction using PPG has a high multi-valued mapping factor of 33.2% and low mutual information of 9.8%. In comparison, heart rate prediction using PPG, a well-established task, has a very low multi-valued mapping factor of 0.75% and high mutual information of 87.7%. We argue that these results provide a more realistic representation of the current progress towards to goal of wearable blood pressure measurement via PPG pulse wave analysis.

arXiv:2301.08439

Schrödinger Spectrum based Continuous Cuff-less Blood Pressure Estimation using Clinically Relevant Features from PPG Signal and its Second Derivative

The presented study aims to estimate blood pressure (BP) using photoplethysmogram (PPG) signals while employing multiple machine learning models. The study proposes a novel algorithm for signal reconstruction, which utilizes the semi-classical signal analysis (SCSA) technique. The proposed algorithm optimises the semi-classical constant and eliminates the trade-off between complexity and accuracy in reconstruction. The reconstructed signals' spectral features are extracted and incorporated with clinically relevant PPG and its second derivative's (SDPPG) morphological features. The developed method was assessed using a publicly available virtual in-silico dataset with more than 4000 subjects, and the Multi-Parameter Intelligent Monitoring in Intensive Care Units dataset. Results showed that the method attained a mean absolute error of 5.37 and 2.96 mmHg for systolic and diastolic BP, respectively, using the CatBoost supervisory algorithm. This approach met the standards set by the Advancement of Medical Instrumentation, and achieved Grade A for all BP categories in the British Hypertension Society protocol. The proposed framework performs well even when applied to a combined database of the MIMIC-III and the Queensland dataset. This study also evaluates the proposed method's performance in a non-clinical setting with noisy and deformed PPG signals, to validate the efficacy of the SCSA method. The noise stress tests showed that the algorithm maintained its key feature detection, signal reconstruction capability, and estimation accuracy up to a 10 dB SNR ratio. It is believed that the proposed cuff-less BP estimation technique has the potential to perform well on resource-constrained settings due to its straightforward implementation approach.

arXiv:2112.15271

BP-Net: Cuff-less, Calibration-free, and Non-invasive Blood Pressure Estimation via a Generic Deep Convolutional Architecture

Objective: The paper focuses on development of robust and accurate processing solutions for continuous and cuff-less blood pressure (BP) monitoring. In this regard, a robust deep learning-based framework is proposed for computation of low latency, continuous, and calibration-free upper and lower bounds on the systolic and diastolic BP. Method: Referred to as the BP-Net, the proposed framework is a novel convolutional architecture that provides longer effective memory while achieving superior performance due to incorporation of casual dialated convolutions and residual connections. To utilize the real potential of deep learning in extraction of intrinsic features (deep features) and enhance the long-term robustness, the BP-Net uses raw Electrocardiograph (ECG) and Photoplethysmograph (PPG) signals without extraction of any form of hand-crafted features as it is common in existing solutions. Results: By capitalizing on the fact that datasets used in recent literature are not unified and properly defined, a benchmark dataset is constructed from the MIMIC-I and MIMIC-III databases obtained from PhysioNet. The proposed BP-Net is evaluated based on this benchmark dataset demonstrating promising performance and shows superior generalizable capacity. Conclusion: The proposed BP-Net architecture is more accurate than canonical recurrent networks and enhances the long-term robustness of the BP estimation task. Significance: The proposed BP-Net architecture addresses key drawbacks of existing BP estimation solutions, i.e., relying heavily on extraction of hand-crafted features, such as pulse arrival time (PAT), and; Lack of robustness. Finally, the constructed BP-Net dataset provides a unified base for evaluation and comparison of deep learning-based BP estimation algorithms.

arXiv:2111.14558

BP-Net: Efficient Deep Learning for Continuous Arterial Blood Pressure Estimation using Photoplethysmogram

Blood pressure (BP) is one of the most influential bio-markers for cardiovascular diseases and stroke; therefore, it needs to be regularly monitored to diagnose and prevent any advent of medical complications. Current cuffless approaches to continuous BP monitoring, though non-invasive and unobtrusive, involve explicit feature engineering surrounding fingertip Photoplethysmogram (PPG) signals. To circumvent this, we present an end-to-end deep learning solution, BP-Net, that uses PPG waveform to estimate Systolic BP (SBP), Mean Average Pressure (MAP), and Diastolic BP (DBP) through intermediate continuous Arterial BP (ABP) waveform. Under the terms of the British Hypertension Society (BHS) standard, BP-Net achieves Grade A for DBP and MAP estimation and Grade B for SBP estimation. BP-Net also satisfies Advancement of Medical Instrumentation (AAMI) criteria for DBP and MAP estimation and achieves Mean Absolute Error (MAE) of 5.16 mmHg and 2.89 mmHg for SBP and DBP, respectively. Further, we establish the ubiquitous potential of our approach by deploying BP-Net on a Raspberry Pi 4 device and achieve 4.25 ms inference time for our model to translate the PPG waveform to ABP waveform.

arXiv:2110.06996

A Novel Clustering-Based Algorithm for Continuous and Non-invasive Cuff-Less Blood Pressure Estimation

Extensive research has been performed on continuous, non-invasive, cuffless blood pressure (BP) measurement using artificial intelligence algorithms. This approach involves extracting certain features from physiological signals like ECG, PPG, ICG, BCG, etc. as independent variables and extracting features from Arterial Blood Pressure (ABP) signals as dependent variables, and then using machine learning algorithms to develop a blood pressure estimation model based on these data. The greatest challenge of this field is the insufficient accuracy of estimation models. This paper proposes a novel blood pressure estimation method with a clustering step for accuracy improvement. The proposed method involves extracting Pulse Transit Time (PTT), PPG Intensity Ratio (PIR), and Heart Rate (HR) features from Electrocardiogram (ECG) and Photoplethysmogram (PPG) signals as the inputs of clustering and regression, extracting Systolic Blood Pressure (SBP) and Diastolic Blood Pressure (DBP) features from ABP signals as dependent variables, and finally developing regression models by applying Gradient Boosting Regression (GBR), Random Forest Regression (RFR), and Multilayer Perceptron Regression (MLP) on each cluster. The method was implemented using the MIMICII dataset with the silhouette criterion used to determine the optimal number of clusters. The results showed that because of the inconsistency, high dispersion, and multi-trend behavior of the extracted features vectors, the accuracy can be significantly improved by running a clustering algorithm and then developing a regression model on each cluster, and finally weighted averaging of the results based on the error of each cluster. When implemented with 5 clusters and GBR, this approach yielded an MAE of 2.56 for SBP estimates and 2.23 for DBP estimates, which were significantly better than the best results without clustering (DBP: 6.27, SBP: 6.36).