Optical coherence tomography angiography (OCTA) is a non-invasive imaging technique widely used to study vascular structures and micro-circulation dynamics in the retina and choroid. OCTA has been widely used in clinics for diagnosing ocular disease and monitoring its progression, because OCTA is safer and faster than dye-based angiography while retaining the ability to characterize micro-scale structures. However, OCTA data contains many inherent noises from the devices and acquisition protocols and suffers from various types of artifacts, which impairs diagnostic accuracy and repeatability. Deep learning (DL) based imaging analysis models are able to automatically detect and remove artifacts and noises, and enhance the quality of image data. It is also a powerful tool for segmentation and identification of normal and pathological structures in the images. Thus, the value of OCTA imaging can be significantly enhanced by the DL-based approaches for interpreting and performing measurements and predictions on the OCTA data. In this study, we reviewed literature on the DL models for OCTA images in the latest five years. In particular, we focused on discussing the current problems in the OCTA data and the corresponding design principles of the DL models. We also reviewed the state-of-art DL models for 3D volumetric reconstruction of the vascular networks and pathological structures such as the edema and distorted optic disc. In addition, the publicly available dataset of OCTA images are summarized at the end of this review. Overall, this review can provide valuable insights for engineers to develop novel DL models by utilizing the characteristics of OCTA signals and images. The pros and cons of each DL methods and their applications discussed in this review can be helpful to assist technicians and clinicians to use proper DL models for fundamental research and disease screening.
Non-line-of-Sight (NLOS) imaging systems collect light at a diffuse relay surface and input this measurement into computational algorithms that output a 3D volumetric reconstruction. These algorithms utilize the Fast Fourier Transform (FFT) to accelerate the reconstruction process but require both input and output to be sampled spatially with uniform grids. However, the geometry of NLOS imaging inherently results in non-uniform sampling on the relay surface when using multi-pixel detector arrays, even though such arrays significantly reduce acquisition times. Furthermore, using these arrays increases the data rate required for sensor readout, posing challenges for real-world deployment. In this work, we utilize the phasor field framework to demonstrate that existing NLOS imaging setups typically oversample the relay surface spatially, explaining why the measurement can be compressed without significantly sacrificing reconstruction quality. This enables us to utilize the Non-Uniform Fast Fourier Transform (NUFFT) to reconstruct from sparse measurements acquired from irregularly sampled relay surfaces of arbitrary shapes. Furthermore, we utilize the NUFFT to reconstruct at arbitrary locations in the hidden volume, ensuring flexible sampling schemes for both the input and output. Finally, we utilize the Scaled Fast Fourier Transform (SFFT) to reconstruct larger volumes without increasing the number of samples stored in memory. All algorithms introduced in this paper preserve the computational complexity of FFT-based methods, ensuring scalability for practical NLOS imaging applications.
Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) are crucial technologies in the field of medical imaging. Score-based models have proven to be effective in addressing different inverse problems encountered in CT and MRI, such as sparse-view CT and fast MRI reconstruction. However, these models face challenges in achieving accurate three dimensional (3D) volumetric reconstruction. The existing score-based models primarily focus on reconstructing two dimensional (2D) data distribution, leading to inconsistencies between adjacent slices in the reconstructed 3D volumetric images. To overcome this limitation, we propose a novel two-and-a-half order score-based model (TOSM). During the training phase, our TOSM learns data distributions in 2D space, which reduces the complexity of training compared to directly working on 3D volumes. However, in the reconstruction phase, the TOSM updates the data distribution in 3D space, utilizing complementary scores along three directions (sagittal, coronal, and transaxial) to achieve a more precise reconstruction. The development of TOSM is built on robust theoretical principles, ensuring its reliability and efficacy. Through extensive experimentation on large-scale sparse-view CT and fast MRI datasets, our method demonstrates remarkable advancements and attains state-of-the-art results in solving 3D ill-posed inverse problems. Notably, the proposed TOSM effectively addresses the inter-slice inconsistency issue, resulting in high-quality 3D volumetric reconstruction.
We propose a deep learning method for 3D volumetric reconstruction in low-dose helical cone-beam computed tomography. Prior machine learning approaches require reference reconstructions computed by another algorithm for training. In contrast, we train our model in a fully self-supervised manner using only noisy 2D X-ray data. This is enabled by incorporating a fast differentiable CT simulator in the training loop. As we do not rely on reference reconstructions, the fidelity of our results is not limited by their potential shortcomings. We evaluate our method on real helical cone-beam projections and simulated phantoms. Our results show significantly higher visual fidelity and better PSNR over techniques that rely on existing reconstructions. When applied to full-dose data, our method produces high-quality results orders of magnitude faster than iterative techniques.
Human body volume estimation from a single RGB image is a challenging problem despite minimal attention from the research community. However VolNet, an architecture leveraging 2D and 3D pose estimation, body part segmentation and volume regression extracted from a single 2D RGB image combined with the subject's body height can be used to estimate the total body volume. VolNet is designed to predict the 2D and 3D pose as well as the body part segmentation in intermediate tasks. We generated a synthetic, large-scale dataset of photo-realistic images of human bodies with a wide range of body shapes and realistic poses called SURREALvols. By using Volnet and combining multiple stacked hourglass networks together with ResNeXt, our model correctly predicted the volume in ~82% of cases with a 10% tolerance threshold. This is a considerable improvement compared to state-of-the-art solutions such as BodyNet with only a ~38% success rate.
This paper studies the problem of 3D volumetric reconstruction from two views of a scene with an unknown camera. While seemingly easy for humans, this problem poses many challenges for computers since it requires simultaneously reconstructing objects in the two views while also figuring out their relationship. We propose a new approach that estimates reconstructions, distributions over the camera/object and camera/camera transformations, as well as an inter-view object affinity matrix. This information is then jointly reasoned over to produce the most likely explanation of the scene. We train and test our approach on a dataset of indoor scenes, and rigorously evaluate the merits of our joint reasoning approach. Our experiments show that it is able to recover reasonable scenes from sparse views, while the problem is still challenging. Project site: https://jasonqsy.github.io/Associative3D
Cryo-electron microscopy (cryo-EM) is a powerful technique for determining the structure of proteins and other macromolecular complexes at near-atomic resolution. In single particle cryo-EM, the central problem is to reconstruct the three-dimensional structure of a macromolecule from $10^{4-7}$ noisy and randomly oriented two-dimensional projections. However, the imaged protein complexes may exhibit structural variability, which complicates reconstruction and is typically addressed using discrete clustering approaches that fail to capture the full range of protein dynamics. Here, we introduce a novel method for cryo-EM reconstruction that extends naturally to modeling continuous generative factors of structural heterogeneity. This method encodes structures in Fourier space using coordinate-based deep neural networks, and trains these networks from unlabeled 2D cryo-EM images by combining exact inference over image orientation with variational inference for structural heterogeneity. We demonstrate that the proposed method, termed cryoDRGN, can perform ab initio reconstruction of 3D protein complexes from simulated and real 2D cryo-EM image data. To our knowledge, cryoDRGN is the first neural network-based approach for cryo-EM reconstruction and the first end-to-end method for directly reconstructing continuous ensembles of protein structures from cryo-EM images.
Single-particle electron cryomicroscopy is an essential tool for high-resolution 3D reconstruction of proteins and other biological macromolecules. An important challenge in cryo-EM is the reconstruction of non-rigid molecules with parts that move and deform. Traditional reconstruction methods fail in these cases, resulting in smeared reconstructions of the moving parts. This poses a major obstacle for structural biologists, who need high-resolution reconstructions of entire macromolecules, moving parts included. To address this challenge, we present a new method for the reconstruction of macromolecules exhibiting continuous heterogeneity. The proposed method uses projection images from multiple viewing directions to construct a graph Laplacian through which the manifold of three-dimensional conformations is analyzed. The 3D molecular structures are then expanded in a basis of Laplacian eigenvectors, using a novel generalized tomographic reconstruction algorithm to compute the expansion coefficients. These coefficients, which we name spectral volumes, provide a high-resolution visualization of the molecular dynamics. We provide a theoretical analysis and evaluate the method empirically on several simulated data sets.
Highly accurate 3D volumetric reconstruction is still an open research topic where the main difficulty is usually related to merging some rough estimations with high frequency details. One of the most promising methods is the fusion between multi-view stereo and photometric stereo images. Beside the intrinsic difficulties that multi-view stereo and photometric stereo in order to work reliably, supplementary problems arise when considered together. In this work, we present a volumetric approach to the multi-view photometric stereo problem. The key point of our method is the signed distance field parameterisation and its relation to the surface normal. This is exploited in order to obtain a linear partial differential equation which is solved in a variational framework, that combines multiple images from multiple points of view in a single system. In addition, the volumetric approach is naturally implemented on an octree, which allows for fast ray-tracing that reliably alleviates occlusions and cast shadows. Our approach is evaluated on synthetic and real data-sets and achieves state-of-the-art results.
As experts continue to debate the optimal surgery practice for coronary disease - percutaneous coronary intervention (PCI) or coronary aortic bypass graft (CABG) - computational tools may provide a quantitative assessment of each option. Computational fluid dynamics (CFD) has been used to assess the interplay between hemodynamics and stent struts; it is of particular interest in Bioresorbable Vascular Stents (BVS), since their thicker struts may result in impacted flow patterns and possible pathological consequences. Many proofs of concept are presented in the literature; however, a practical method for extracting patient-specific stented coronary artery geometries from images over a large number of patients remains an open problem. This work provides a possible pipeline for the reconstruction of the BVS. Using Optical Coherence Tomographies (OCT) and Invasive Coronary Angiographies (ICA), we can reconstruct the 3D geometry of deployed BVS in vivo. We illustrate the stent reconstruction process: (i) automatic strut detection, (ii) identification of stent components, (iii) 3D registration of stent curvature, and (iv) final stent volume reconstruction. The methodology is designed for use on clinical OCT images, as opposed to approaches that relied on a small number of virtually deployed stents. The proposed reconstruction process is validated with a virtual phantom stent, providing quantitative assessment of the methodology, and with selected clinical cases, confirming feasibility. Using multimodality image analysis, we obtain reliable reconstructions within a reasonable timeframe. This work is the first step toward a fully automated reconstruction and simulation procedure aiming at an extensive quantitative analysis of the impact of BVS struts on hemodynamics via CFD in clinical trials, going beyond the proof-of-concept stage.