Papers with Code · CC BY-SA 4.0

데이터셋 탐색

데이터셋의 설명·홈페이지를 찾고, 관련 태스크의 평가 기록을 살펴보세요.

관련 논문 19편

Physion

Physion 설명 보기

Physion is a visual and physical prediction benchmark to measure the performance of machine learning models on making predictions about commonplace real world physical events. In realistically simulating a wide variety of physical phenomena -- rigid and soft-body collisions, stable multi-object configurations, rolling and sliding, projectile motion -- this dataset presents a more comprehensive challenge than existing benchmarks. Moreover, the dataset also contains human responses for the stimuli so that model predictions can be directly compared to human judgments.

관련 논문 23편

PhysioNet Challenge 2012

PhysioNet Challenge 2012 설명 보기

The PhysioNet Challenge 2012 dataset is publicly available and contains the de-identified records of 8000 patients in Intensive Care Units (ICU). Each record consists of roughly 48 hours of multivariate time series data with up to 37 features recorded at various times from the patients during their stay such as respiratory rate, glucose etc. Source: Multi-resolution Networks For Flexible Irregular Time Series Modeling (Multi-FIT) Image Source: https://physionet.org/content/challenge-2016/1.0.0/

관련 논문 6편

The PhysioNet/Computing in Cardiology Challenge 2021

PhysioNet Challenge 2021
PhysioNet Challenge 2021 설명 보기

Data Description The training data contains twelve-lead ECGs. The validation and test data contains twelve-lead, six-lead, four-lead, three-lead, and two-lead ECGs: 1. Twelve leads: I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6 2. Six leads: I, II, III, aVR, aVL, aVF 3. Four leads: I, II, III, V2 4. Three leads: I, II, V2 5. Two leads: I, II Each ECG recording has one or more labels that describe cardiac abnormalities (and/or a normal sinus rhythm). We mapped the labels for each recording to SNOMED-CT codes. The lists of scored labels and unscored labels are given with the evaluation code; see the scoring section for details. # Data Sources The Challenge data include recordings from last year’s Challenge and many new recordings for this year’s Challenge: 1. CPSC Database and CPSC-Extra Database 2. INCART Database 3. PTB and PTB-XL Database 4. The Georgia 12-lead ECG Challenge (G12EC) Database 5. Augmented Undisclosed Database 6. Chapman-Shaoxing and Ningbo Database 7. The University of Michigan (UMich) Database The Challenge data include annotated twelve-lead ECG recordings from six sources in four countries across three continents. These databases include over 100,000 twelve-lead ECG recordings with over 88,000 ECGs shared publicly as training data, 6,630 ECGs retained privately as validation data, and 36,266 ECGs retained privately as test data. - The first source is the China Physiological Signal Challenge in 2018 (CPSC 2018), which was held during the 7th International Conference on Biomedical Engineering and Biotechnology in Nanjing, China. This source contains two databases: the data from CPSC 2018 (the CPSC Database) and unused data from CPSC 2018 (the CPSC-Extra Database). Together, these databases contain 13,256 ECGs (10,330 ECGs shared as training data, 1,463 retained as validation data, and 1,463 retained as test data). We shared the training set and an unused dataset from CPSC 2018 as training data, and we split the test set from CPSC 2018 into validation and test sets. Each recording is between 6 and 144 seconds long with a sampling frequency of 500 Hz. - The second source is the St Petersburg INCART 12-lead Arrhythmia Database. This source contains 74 annotated ECGs (all shared as training data) extracted from 32 Holter monitor recordings. Each recording is 30 minutes long with a sampling frequency of 257 Hz. - The third source is the Physikalisch-Technische Bundesanstalt (PTB) and includes two public datasets: the PTB and the PTB-XL databases. The source contains 22,353 ECGs (all shared as training data). Each recording is between 10 and 120 seconds long with a sampling frequency of either 500 or 1,000 Hz. - The fourth source is a Georgia database which represents a unique demographic of the Southeastern United States. This source contains 20,672 ECGs (10,344 ECGs shared as training data, 5,167 retained as validation data, and 5,161 retained as test data). Each recording is between 5 and 10 seconds long with a sampling frequency of 500 Hz. - The fifth source is an undisclosed American database that is geographically distinct from the Georgia database. This source contains 10,000 ECGs (all retained as test data). - The sixth source is the Chapman University, Shaoxing People’s Hospital (Chapman-Shaoxing) and Ningbo First Hospital (Ningbo) database. This source contains 45,152 ECGS (all shared as training data). Each recording is 10 seconds long with a sampling frequency of 500 Hz. - The seventh source is UMich Database from the University of Michigan. This source contains 19,642 ECGs (all retained as test data). Each recording is 10 seconds long with a sampling frequency of either 250 Hz or 500 Hz. Like other real-world datasets, different databases may have different proportions of cardiac abnormalities, but all of the labels in the validation or test data are represented in the training data. Moreover, while this is a curated dataset, some of the data and labels are likely to have errors, and an important part of the Challenge is to work out these issues. In particular, some of the databases have human-overread machine labels with single or multiple human readers, so the quality of the labels varies between databases. You can find more information about the label mappings of the Challenge training data in this table. The six-lead, four-lead, three-lead, and two-lead validation data are reduced-lead versions of the twelve-lead validation data: the same recordings with the same header data but only with signal data for the relevant leads. We are not planning to release the test data at any point, including after the end of the Challenge. Requests for the test data will not receive a response. We do not release test data to prevent overfitting on the test data and claims or publications of inflated performances. We will entertain requests to run code on the test data after the Challenge on a limited basis based on publication necessity and capacity. (The Challenge is largely staged by volunteers.) # Data Format All data was formatted in WFDB format. Each ECG recording uses a binary MATLAB v4 file (see page 27) for the ECG signal data and a plain text file in WFDB header format for the recording and patient attributes, including the diagnosis, i.e., the labels for the recording. The binary files can be read using the load function in MATLAB and the scipy.io.loadmat function in Python; see our MATLAB and Python example code for working examples. The first line of the header provides information about the total number of leads and the total number of samples or time points per lead, the following lines describe how each lead was encoded, and the last lines provide information on the demographics and diagnosis of the patient. For example, a header file A0001.hea may have the following contents: A0001 12 500 7500 05-Feb-2020 11:39:16 A0001.mat 16+24 1000/mV 16 0 28 -1716 0 I A0001.mat 16+24 1000/mV 16 0 7 2029 0 II A0001.mat 16+24 1000/mV 16 0 -21 3745 0 III A0001.mat 16+24 1000/mV 16 0 -17 3680 0 aVR A0001.mat 16+24 1000/mV 16 0 24 -2664 0 aVL A0001.mat 16+24 1000/mV 16 0 -7 -1499 0 aVF A0001.mat 16+24 1000/mV 16 0 -290 390 0 V1 A0001.mat 16+24 1000/mV 16 0 -204 157 0 V2 A0001.mat 16+24 1000/mV 16 0 -96 -2555 0 V3 A0001.mat 16+24 1000/mV 16 0 -112 49 0 V4 A0001.mat 16+24 1000/mV 16 0 -596 -321 0 V5 A0001.mat 16+24 1000/mV 16 0 -16 -3112 0 V6 #Age: 74 #Sex: Male #Dx: 426783006 #Rx: Unknown #Hx: Unknown #Sx: Unknown From the first line of the file, we see that the recording number is A0001, and the recording file is A0001.mat. The recording has 12 leads, each recorded at a 500 Hz sampling frequency, and contains 7500 samples. From the next 12 lines of the file (one for each lead), we see that each signal was written at 16 bits with an offset of 24 bits, the floating point number (analog-to-digital converter (ADC) units per physical unit) is 1000/mV, the resolution of the analog-to-digital converter (ADC) used to digitize the signal is 16 bits, and the baseline value corresponding to 0 physical units is 0. The first value of the signal (-1716, etc.), the checksum (0, etc.), and the lead name (I, etc.) are the last three entries of each of these lines. From the final 6 lines, we see that the patient is a 74-year-old male with a diagnosis (Dx) of 426783006, which is the SNOMED-CT code for sinus rhythm. The medical prescription (Rx), history (Hx), and symptom or surgery (Sx) are unknown. Please visit WFDB header format for more information on the header file and variables.

관련 논문 5편

AF Classification from a Short Single Lead ECG Recording - The PhysioNet Computing in Cardiology Challenge 2017

AF Classification from a Short Single Lead ECG Recording - The PhysioNet Computing in Cardiology Challenge 2017 설명 보기

The 2017 PhysioNet/CinC Challenge aims to encourage the development of algorithms to classify, from a single short ECG lead recording (between 30 s and 60 s in length), whether the recording shows normal sinus rhythm, atrial fibrillation (AF), an alternative rhythm, or is too noisy to be classified.

관련 논문 4편

Digitization and Classification of ECG Images: The George B. Moody PhysioNet Challenge 2024

ECG-Image-Database
ECG-Image-Database 설명 보기

The George B. Moody PhysioNet Challenges are annual competitions that invite participants to develop automated approaches for addressing important physiological and clinical problems. The 2024 Challenge invites teams to develop algorithms for digitizing and classifying electrocardiograms (ECGs) captured from images or paper printouts. Despite the recent advances in digital ECG devices, physical or paper ECGs remain common, especially in the Global South. These physical ECGs document the history and diversity of cardiovascular diseases (CVDs), and algorithms that can digitize and classify these images have the potential to improve our understanding and treatment of CVDs, especially for underrepresented and underserved populations.

관련 논문 4편

You Snooze You Win - The PhysioNet Computing in Cardiology Challenge 2018

PhysioNet Challenge 2018
PhysioNet Challenge 2018 설명 보기

Data for this challenge were contributed by the Massachusetts General Hospital’s (MGH) Computational Clinical Neurophysiology Laboratory (CCNL), and the Clinical Data Animation Laboratory (CDAC). The dataset includes 1,985 subjects which were monitored at an MGH sleep laboratory for the diagnosis of sleep disorders. The data were partitioned into balanced training (n = 994), and test sets (n = 989). The sleep stages of the subjects were annotated by clinical staff at the MGH according to the American Academy of Sleep Medicine (AASM) manual for the scoring of sleep. More specifically, the following six sleep stages were annotated in 30 second contiguous intervals: wakefulness, stage 1, stage 2, stage 3, rapid eye movement (REM), and undefined. Certified sleep technologists at the MGH also annotated waveforms for the presence of arousals that interrupted the sleep of the subjects. The annotated arousals were classified as either: spontaneous arousals, respiratory effort related arousals (RERA), bruxisms, hypoventilations, hypopneas, apneas (central, obstructive and mixed), vocalizations, snores, periodic leg movements, Cheyne-Stokes breathing or partial airway obstructions. The subjects had a variety of physiological signals recorded as they slept through the night including: electroencephalography (EEG), electrooculography (EOG), electromyography (EMG), electrocardiology (EKG), and oxygen saturation (SaO2). Excluding SaO2, all signals were sampled to 200 Hz and were measured in microvolts. For analytic convenience, SaO2 was resampled to 200 Hz, and is measured as a percentage.

관련 논문 4편

PhysioNet Challenge 2020

PhysioNet Challenge 2020 설명 보기

Data ## The data for this Challenge are from multiple sources: CPSC Database and CPSC-Extra Database INCART Database PTB and PTB-XL Database The Georgia 12-lead ECG Challenge (G12EC) Database Undisclosed Database The first source is the public (CPSC Database) and unused data (CPSC-Extra Database) from the China Physiological Signal Challenge in 2018 (CPSC2018), held during the 7th International Conference on Biomedical Engineering and Biotechnology in Nanjing, China. The unused data from the CPSC2018 is NOT the test data from the CPSC2018. The test data of the CPSC2018 is included in the final private database that has been sequestered. This training set consists of two sets of 6,877 (male: 3,699; female: 3,178) and 3,453 (male: 1,843; female: 1,610) of 12-ECG recordings lasting from 6 seconds to 60 seconds. Each recording was sampled at 500 Hz. The second source set is the public dataset from St Petersburg INCART 12-lead Arrhythmia Database. This database consists of 74 annotated recordings extracted from 32 Holter records. Each record is 30 minutes long and contains 12 standard leads, each sampled at 257 Hz. The third source from the Physikalisch Technische Bundesanstalt (PTB) comprises two public databases: the PTB Diagnostic ECG Database and the PTB-XL, a large publicly available electrocardiography dataset. The first PTB database contains 516 records (male: 377, female: 139). Each recording was sampled at 1000 Hz. The PTB-XL contains 21,837 clinical 12-lead ECGs (male: 11,379 and female: 10,458) of 10 second length with a sampling frequency of 500 Hz. The fourth source is a Georgia database which represents a unique demographic of the Southeastern United States. This training set contains 10,344 12-lead ECGs (male: 5,551, female: 4,793) of 10 second length with a sampling frequency of 500 Hz. The fifth source is an undisclosed American database that is geographically distinct from the Georgia database. This source contains 10,000 ECGs (all retained as test data). All data is provided in WFDB format. Each ECG recording has a binary MATLAB v4 file (see page 27) for the ECG signal data and a text file in WFDB header format describing the recording and patient attributes, including the diagnosis (the labels for the recording). The binary files can be read using the load function in MATLAB and the scipy.io.loadmat function in Python; please see our baseline models for examples of loading the data. The first line of the header provides information about the total number of leads and the total number of samples or points per lead. The following lines describe how each lead was saved, and the last lines provide information on demographics and diagnosis. Below is an example header file A0001.hea: A0001 12 500 7500 05-Feb-2020 11:39:16 A0001.mat 16+24 1000/mV 16 0 28 -1716 0 I A0001.mat 16+24 1000/mV 16 0 7 2029 0 II A0001.mat 16+24 1000/mV 16 0 -21 3745 0 III A0001.mat 16+24 1000/mV 16 0 -17 3680 0 aVR A0001.mat 16+24 1000/mV 16 0 24 -2664 0 aVL A0001.mat 16+24 1000/mV 16 0 -7 -1499 0 aVF A0001.mat 16+24 1000/mV 16 0 -290 390 0 V1 A0001.mat 16+24 1000/mV 16 0 -204 157 0 V2 A0001.mat 16+24 1000/mV 16 0 -96 -2555 0 V3 A0001.mat 16+24 1000/mV 16 0 -112 49 0 V4 A0001.mat 16+24 1000/mV 16 0 -596 -321 0 V5 A0001.mat 16+24 1000/mV 16 0 -16 -3112 0 V6 #Age: 74 #Sex: Male #Dx: 426783006 #Rx: Unknown #Hx: Unknown #Sx: Unknown From the first line, we see that the recording number is A0001, and the recording file is A0001.mat. The recording has 12 leads, each recorded at 500 Hz sample frequency, and contains 7500 samples. From the next 12 lines, we see that each signal was written at 16 bits with an offset of 24 bits, the amplitude resolution is 1000 with units in mV, the resolution of the analog-to-digital converter (ADC) used to digitize the signal is 16 bits, and the baseline value corresponding to 0 physical units is 0. The first value of the signal, the checksum, and the lead name are included for each signal. From the final 6 lines, we see that the patient is a 74-year-old male with a diagnosis (Dx) of 426783006. The medical prescription (Rx), history (Hx), and symptom or surgery (Sx) are unknown. Each ECG recording has one or more labels from different type of abnormalities in SNOMED-CT codes. The full list of diagnoses for the challenge has been posted here as a 3 column CSV file: Long-form description, corresponding SNOMED-CT code, abbreviation. Although these descriptions apply to all training data there may be fewer classes in the test data, and in different proportions. However, every class in the test data will be represented in the training data.

관련 논문 3편

PhysioNet Apnea-ECG Database

Apnea-ECG
Apnea-ECG 설명 보기

The data consist of 70 records, divided into a learning set of 35 records (a01 through a20, b01 through b05, and c01 through c10), and a test set of 35 records (x01 through x35), all of which may be downloaded from this page. Recordings vary in length from slightly less than 7 hours to nearly 10 hours each. Each recording includes a continuous digitized ECG signal, a set of apnea annotations (derived by human experts on the basis of simultaneously recorded respiration and related signals), and a set of machine-generated QRS annotations (in which all beats regardless of type have been labeled normal). In addition, eight recordings (a01 through a04, b01, and c01 through c03) are accompanied by four additional signals (Resp C and Resp A, chest and abdominal respiratory effort signals obtained using inductance plethysmography; Resp N, oronasal airflow measured using nasal thermistors; and SpO2, oxygen saturation).

관련 논문 3편

Physionet EEG Motor Movement/Imagery Dataset

Physionet MI
Physionet MI 설명 보기

This data set consists of over 1500 one- and two-minute EEG recordings, obtained from 109 volunteers [2]. Subjects performed different motor/imagery tasks while 64-channel EEG were recorded using the BCI2000 system (http://www.bci2000.org) [1]. Each subject performed 14 experimental runs: two one-minute baseline runs (one with eyes open, one with eyes closed), and three two-minute runs of each of the four following tasks: - A target appears on either the left or the right side of the screen. The subject opens and closes the corresponding fist until the target disappears. Then the subject relaxes. - A target appears on either the left or the right side of the screen. The subject imagines opening and closing the corresponding fist until the target disappears. Then the subject relaxes. - A target appears on either the top or the bottom of the screen. The subject opens and closes either both fists (if the target is on top) or both feet (if the target is on the bottom) until the target disappears. Then the subject relaxes. - A target appears on either the top or the bottom of the screen. The subject imagines opening and closing either both fists (if the target is on top) or both feet (if the target is on the bottom) until the target disappears. Then the subject relaxes. References [1] Schalk, G., McFarland, D.J., Hinterberger, T., Birbaumer, N. and Wolpaw, J.R., 2004. BCI2000: a general-purpose brain-computer interface (BCI) system. IEEE Transactions on biomedical engineering, 51(6), pp.1034-1043. [2] Goldberger, A.L., Amaral, L.A., Glass, L., Hausdorff, J.M., Ivanov, P.C., Mark, R.G., Mietus, J.E., Moody, G.B., Peng, C.K., Stanley, H.E. and PhysioBank, P., PhysioNet: components of a new research resource for complex physiologic signals Circulation 2000 Volume 101 Issue 23 pp. E215–E220.

관련 논문 2편

PhysioNet Challenge 2016

PhysioNet Challenge 2016 설명 보기

Introduction The 2016 PhysioNet/CinC Challenge aims to encourage the development of algorithms to classify heart sound recordings collected from a variety of clinical or nonclinical (such as in-home visits) environments. The aim is to identify, from a single short recording (10-60s) from a single precordial location, whether the subject of the recording should be referred on for an expert diagnosis. During the cardiac cycle, the heart firstly generates the electrical activity and then the electrical activity causes atrial and ventricular contractions. This in turn forces blood between the chambers of the heart and around the body. The opening and closure of the heart valves is associated with accelerations-decelerations of blood, giving rise to vibrations of the entire cardiac structure (the heart sounds and murmurs) [1]. These vibrations are audible at the chest wall, and listening for specific heart sounds can give an indication of the health of the heart. The phonocardiogram (PCG) is the graphical representation of a heart sound recording. Figure 1 illustrates a short section of a PCG recording.

관련 논문 2편

PhysioNet Challenge 2019

PhysioNet Challenge 2019 설명 보기

Early Prediction of Sepsis from Clinical Data: The PhysioNet/Computing in Cardiology Challenge 2019 The goal of this Challenge is the early detection of sepsis using physiological data. Sepsis is a major public health concern with significant morbidity, mortality, and healthcare expenses. Early detection and antibiotic treatment of sepsis improve outcomes. However, although professional critical care societies have proposed new clinical criteria that aid sepsis recognition, the fundamental need for early detection and treatment remains unmet. In response, researchers have proposed algorithms for early sepsis detection, but directly comparing such methods has not been possible because of different patient cohorts, clinical variables and sepsis criteria, prediction tasks, evaluation metrics, and other differences. To address these issues, the PhysioNet/Computing in Cardiology Challenge 2019 facilitated the development of automated, open-source algorithms for the early detection of sepsis from clinical data. The data consist of 40 time-dependent health variables measured on 40,336 subjects.

관련 논문 1편

Physionet Siena Scalp EEG Database

Siena Scalp EEG Database
Siena Scalp EEG Database 설명 보기

The database consists of EEG recordings of 14 patients acquired at the Unit of Neurology and Neurophysiology of the University of Siena. Subjects include 9 males (ages 25-71) and 5 females (ages 20-58). Subjects were monitored with a Video-EEG with a sampling rate of 512 Hz, with electrodes arranged on the basis of the international 10-20 System. Most of the recordings also contain 1 or 2 EKG signals. The diagnosis of epilepsy and the classification of seizures according to the criteria of the International League Against Epilepsy were performed by an expert clinician after a careful review of the clinical and electrophysiological data of each patient.

관련 논문 0편

Physionet Motor Imagery dataset.

Physionet Motor Imagery dataset. 설명 보기

Physionet MI dataset: https://physionet.org/pn4/eegmmidb/ This data set consists of over 1500 one- and two-minute EEG recordings, obtained from 109 volunteers [2]. Subjects performed different motor/imagery tasks while 64-channel EEG were recorded using the BCI2000 system (http://www.bci2000.org) [1]. Each subject performed 14 experimental runs: two one-minute baseline runs (one with eyes open, one with eyes closed), and three two-minute runs of each of the four following tasks: 1. A target appears on either the left or the right side of the screen. The subject opens and closes the corresponding fist until the target disappears. Then the subject relaxes. 2. A target appears on either the left or the right side of the screen. The subject imagines opening and closing the corresponding fist until the target disappears. Then the subject relaxes. 3. A target appears on either the top or the bottom of the screen. The subject opens and closes either both fists (if the target is on top) or both feet (if the target is on the bottom) until the target disappears. Then the subject relaxes. 4. A target appears on either the top or the bottom of the screen. The subject imagines opening and closing either both fists (if the target is on top) or both feet (if the target is on the bottom) until the target disappears. Then the subject relaxes. ## References [1] Schalk, G., McFarland, D.J., Hinterberger, T., Birbaumer, N. and Wolpaw, J.R., 2004. BCI2000: a general-purpose brain-computer interface (BCI) system. IEEE Transactions on biomedical engineering, 51(6), pp.1034-1043. [2] Goldberger, A.L., Amaral, L.A., Glass, L., Hausdorff, J.M., Ivanov, P.C., Mark, R.G., Mietus, J.E., Moody, G.B., Peng, C.K., Stanley, H.E. and PhysioBank, P., PhysioNet: components of a new research resource for complex physiologic signals Circulation 2000 Volume 101 Issue 23 pp. E215–E220.