Papers with Code · CC BY-SA 4.0

데이터셋 탐색

데이터셋의 설명·홈페이지를 찾고, 관련 태스크의 평가 기록을 살펴보세요.

관련 논문 19편

Breast Cancer Immunohistochemical Image Generation

BCI
BCI 설명 보기

The evaluation of human epidermal growth factor receptor 2 (HER2) expression is essential to formulate a precise treatment for breast cancer. The routine evaluation of HER2 is conducted with immunohistochemical techniques (IHC), which is very expensive. Therefore, we propose a breast cancer immunohistochemical (BCI) benchmark attempting to synthesize IHC data directly with the paired hematoxylin and eosin (HE) stained images. The dataset contains 4870 registered image pairs, covering a variety of HER2 expression levels (0, 1+, 2+, 3+).

관련 논문 7편

BCI Competition IV: ECoG to Finger Movements

BCI Competition IV: ECoG to Finger Movements 설명 보기

#####Prediction of Finger Flexion IV Brain-Computer Interface Data Competition The goal of this dataset is to predict the flexion of individual fingers from signals recorded from the surface of the brain (electrocorticography (ECoG)). This data set contains brain signals from three subjects, as well as the time courses of the flexion of each of five fingers. The task in this competition is to use the provided flexion information in order to predict finger flexion for a provided test set. The performance of the classifier will be evaluated by calculating the average correlation coefficient r between actual and predicted finger flexion. ECoG data during individual flexions of the five fingers; movements acquired with a data glove. [48 - 64 ECoG channels (0.15-200Hz), 1000Hz sampling rate, 3 subjects]

관련 논문 0편

EEG dataset and OpenBMI toolbox for three BCI paradigms

BMI/OpenBMI dataset for MI.
BMI/OpenBMI dataset for MI. 설명 보기

BMI/OpenBMI dataset for MI. Dataset from Lee et al 2019 [1]. ### Dataset Description EEG signals were recorded with a sampling rate of 1,000 Hz and collected with 62 Ag/AgCl electrodes. The EEG amplifier used in the experiment was a BrainAmp (Brain Products; Munich, Germany). The channels were nasion-referenced and grounded to electrode AFz. Additionally, an EMG electrode recorded from each flexor digitorum profundus muscle with the olecranon used as reference. The EEG/EMG channel configuration and indexing numbers are described in Fig. 1. The impedances of the EEG electrodes were maintained below 10 k during the entire experiment. MI paradigm The MI paradigm was designed following a well-established system protocol. For all blocks, the first 3 s of each trial began with a black fixation cross that appeared at the center of the monitor to prepare subjects for the MI task. Afterwards, the subject performed the imagery task of grasping with the appropriate hand for 4 s when the right or left arrow appeared as a visual cue. After each task, the screen remained blank for 6 s (± 1.5 s). The experiment consisted of training and test phases; each phase had 100 trials with balanced right and left hand imagery tasks. During the online test phase, the fixation cross appeared at the center of the monitor and moved right or left, according to the real-time classifier output of the EEG signal. ### References [1] Lee, M. H., Kwon, O. Y., Kim, Y. J., Kim, H. K., Lee, Y. E., Williamson, J., … Lee, S. W. (2019). EEG dataset and OpenBMI toolbox for three BCI paradigms: An investigation into BCI illiteracy. GigaScience, 8(5), 1–16. https://doi.org/10.1093/gigascience/giz002

관련 논문 0편

BCI Competition 4, version IIa

BNCI 2014-001 Motor Imagery dataset.
BNCI 2014-001 Motor Imagery dataset. 설명 보기

BNCI 2014-001 Motor Imagery dataset Dataset IIa from BCI Competition 4 [1]. ### Dataset Description This data set consists of EEG data from 9 subjects. The cue-based BCI paradigm consisted of four different motor imagery tasks, namely the imagination of movement of the left hand (class 1), right hand (class 2), both feet (class 3), and tongue (class 4). Two sessions on different days were recorded for each subject. Each session is comprised of 6 runs separated by short breaks. One run consists of 48 trials (12 for each of the four possible classes), yielding a total of 288 trials per session. The subjects were sitting in a comfortable armchair in front of a computer screen. At the beginning of a trial ( t = 0 s), a fixation cross appeared on the black screen. In addition, a short acoustic warning tone was presented. After two seconds ( t = 2 s), a cue in the form of an arrow pointing either to the left, right, down or up (corresponding to one of the four classes left hand, right hand, foot or tongue) appeared and stayed on the screen for 1.25 s. This prompted the subjects to perform the desired motor imagery task. No feedback was provided. The subjects were ask to carry out the motor imagery task until the fixation cross disappeared from the screen at t = 6 s. Twenty-two Ag/AgCl electrodes (with inter-electrode distances of 3.5 cm) were used to record the EEG; the montage is shown in Figure 3 left. All signals were recorded monopolarly with the left mastoid serving as reference and the right mastoid as ground. The signals were sampled with. 250 Hz and bandpass-filtered between 0.5 Hz and 100 Hz. The sensitivity of the amplifier was set to 100 μV . An additional 50 Hz notch filter was enabled to suppress line noise. ### References [1] Tangermann, M., Müller, K.R., Aertsen, A., Birbaumer, N., Braun, C., Brunner, C., Leeb, R., Mehring, C., Miller, K.J., Mueller-Putz, G. and Nolte, G., 2012. Review of the BCI competition IV. Frontiers in neuroscience, 6, p.55.

관련 논문 0편

BCI Competition 4 IIa

BNCI 2014-002 Motor Imagery dataset
BNCI 2014-002 Motor Imagery dataset 설명 보기

Dataset Description This data set consists of EEG data from 9 subjects. The cue-based BCI paradigm consisted of four different motor imagery tasks, namely the imag- ination of movement of the left hand (class 1), right hand (class 2), both feet (class 3), and tongue (class 4). Two sessions on different days were recorded for each subject. Each session is comprised of 6 runs separated by short breaks. One run consists of 48 trials (12 for each of the four possible classes), yielding a total of 288 trials per session. The subjects were sitting in a comfortable armchair in front of a computer screen. At the beginning of a trial ( t = 0 s), a fixation cross appeared on the black screen. In addition, a short acoustic warning tone was presented. After two seconds ( t = 2 s), a cue in the form of an arrow pointing either to the left, right, down or up (corresponding to one of the four classes left hand, right hand, foot or tongue) appeared and stayed on the screen for 1.25 s. This prompted the subjects to perform the desired motor imagery task. No feedback was provided. The subjects were ask to carry out the motor imagery task until the fixation cross disappeared from the screen at t = 6 s. Twenty-two Ag/AgCl electrodes (with inter-electrode distances of 3.5 cm) were used to record the EEG; the montage is shown in Figure 3 left. All signals were recorded monopolarly with the left mastoid serving as reference and the right mastoid as ground. The signals were sampled with. 250 Hz and bandpass-filtered between 0.5 Hz and 100 Hz. The sensitivity of the amplifier was set to 100 μV . An additional 50 Hz notch filter was enabled to suppress line noise References ---------- [1] Tangermann, M., Müller, K.R., Aertsen, A., Birbaumer, N., Braun, C., Brunner, C., Leeb, R., Mehring, C., Miller, K.J., Mueller-Putz, G. and Nolte, G., 2012. Review of the BCI competition IV. Frontiers in neuroscience, 6, p.55.

관련 논문 0편

Dataset B from BCI Competition 2008.

BNCI 2014-004 Motor Imagery dataset.
BNCI 2014-004 Motor Imagery dataset. 설명 보기

Dataset description This data set consists of EEG data from 9 subjects of a study published in [1]_. The subjects were right-handed, had normal or corrected-to-normal vision and were paid for participating in the experiments. All volunteers were sitting in an armchair, watching a flat screen monitor placed approximately 1 m away at eye level. For each subject 5 sessions are provided, whereby the first two sessions contain training data without feedback (screening), and the last three sessions were recorded with feedback. Three bipolar recordings (C3, Cz, and C4) were recorded with a sampling frequency of 250 Hz.They were bandpass- filtered between 0.5 Hz and 100 Hz, and a notch filter at 50 Hz was enabled. The placement of the three bipolar recordings (large or small distances, more anterior or posterior) were slightly different for each subject (for more details see [1]). The electrode position Fz served as EEG ground. In addition to the EEG channels, the electrooculogram (EOG) was recorded with three monopolar electrodes. The cue-based screening paradigm consisted of two classes, namely the motor imagery (MI) of left hand (class 1) and right hand (class 2). Each subject participated in two screening sessions without feedback recorded on two different days within two weeks. Each session consisted of six runs with ten trials each and two classes of imagery. This resulted in 20 trials per run and 120 trials per session. Data of 120 repetitions of each MI class were available for each person in total. Prior to the first motor im- agery training the subject executed and imagined different movements for each body part and selected the one which they could imagine best (e. g., squeezing a ball or pulling a brake). Each trial started with a fixation cross and an additional short acoustic warning tone (1 kHz, 70 ms). Some seconds later a visual cue was presented for 1.25 seconds. Afterwards the subjects had to imagine the corresponding hand movement over a period of 4 seconds. Each trial was followed by a short break of at least 1.5 seconds. A randomized time of up to 1 second was added to the break to avoid adaptation For the three online feedback sessions four runs with smiley feedback were recorded, whereby each run consisted of twenty trials for each type of motor imagery. At the beginning of each trial (second 0) the feedback (a gray smiley) was centered on the screen. At second 2, a short warning beep (1 kHz, 70 ms) was given. The cue was presented from second 3 to 7.5. At second 7.5 the screen went blank and a random interval between 1.0 and 2.0 seconds was added to the trial.