arXiv:2611.20187v1 cs.ET

Cyber-Secure Wearable, Ultra-Low-Power Networked Sensors for Soldier Health Monitoring: Insights from the CAPSARII project

Luciano Bozzi, Christian Celidonio, Umberto Nuzzi, Massimo Biagini, Stefano Cherubin, Asbj{\o}rn Djupdal, Tor Andre Haugdahl, Andrea Aliverti, Alessandra Angelucci, Giovanni Agosta, Gerardo Pelosi, Paolo Belluco, Samuele Polistina, Gaia Strada, Luigi Sossi Ortega 외 7명

제출 2026-11-15

저자 비고

arXiv Comments

Pre-print version

원문 초록

The CAPSARII project advances a cyber-secure, ultra-low-power wearable platform and Internet of Battlefield Things (IoBT) framework to support real-time monitoring of military personnel and data-driven decision support. The architecture integrates smart-textile sensing, a body/squad area mesh, edge-deployed AI on secure RISC-V microcontrollers, and cloud/federated analytics for cross-mission learning and comparative studies. Two representative use cases--pilot fatigue and warfighters operating in harsh environments--guide requirements, validation, and interface design (including HUD and haptic feedback). As an initial step toward embedded models, we benchmark stress classification on a public wearable dataset: tree-ensemble baselines achieve state-of-the-art performance for accuracy and F1 (e.g., XGBoost: $\mathrm{Accuracy}=0.901\!\pm\!0.023$, $\mathrm{F1}=0.920\!\pm\!0.019$), while a feature-based Transformer attains the highest AUC ($0.963\!\pm\!0.025$), informing feature-engineering and compression choices for edge deployment. Building on these results, CAPSARII employs HW/SW co-design, model compression (pruning, quantization, distillation), and precision tuning to meet stringent energy and memory budgets; it further investigates Processing-in-Memory accelerators for future efficiency gains. A structured gap analysis highlights the remaining challenges: establishing validation standards for physiological signal quality and textile durability; achieving low-latency, scalable BAN/SAN communications under mobility and interference; and deploying hybrid lightweight/post-quantum cryptography with robust device identity and side-channel resilience on constrained endpoints. By consolidating these elements into a coherent, secure IoBT stack, CAPSARII delineates a practical roadmap from laboratory baselines to mission-ready soldier monitoring in both training and operational scenarios.

제출 이력

확인된 버전만 표시합니다. 전체 제출 이력은 arXiv 원문에서 확인하세요.

  1. arXiv:2611.20187v1

함께 살펴볼 논문

공통 태그를 근거로 연결했습니다. 실제 인용 관계나 논문의 우수성을 뜻하지 않습니다.

공통 태그로 연결된 공개 논문이 아직 없습니다.

토론

이 논문과 연결된 포럼 글이 아직 없습니다.