arXiv:2611.05011v1 cs.CV

Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation study

Aashish Chapagai, Angad Singh Gurtatta, Erik Cambria

제출 2026-11-04

원문 초록

Saliency maps are offered as a safeguard for medical image classifiers, but whether they reveal individual errors at a new hospital remains largely untested. We trained a convolutional network and a vision transformer on NIH ChestX-ray14 and evaluated 303,768 decisions per model at the training hospital and at two external sites, in the USA and Vietnam, with radiologist-consensus labels. We scored each explanation by its anatomical enrichment, the area-normalized concentration of attribution in a segmented thoracic region, and tested whether it detects errors beyond the model's confidence. Grad-CAM localized findings less often than radiologists (hit rate at most 0.575 versus 0.888). Adding enrichment to a confidence-based error detector calibrated at the training hospital never raised its area under the curve by more than 0.011, and for the convolutional network the relation between enrichment and correctness reversed between hospitals, degrading the transferred detector. Model confidence, not saliency, should anchor deployment monitoring.

제출 이력

확인된 버전만 표시합니다. 전체 제출 이력은 arXiv 원문에서 확인하세요.

  1. arXiv:2611.05011v1제출 시각 미확인

함께 살펴볼 논문

공통 태그를 근거로 연결했습니다. 실제 인용 관계나 논문의 우수성을 뜻하지 않습니다.

공통 태그로 연결된 공개 논문이 아직 없습니다.

토론

이 논문과 연결된 포럼 글이 아직 없습니다.