arXiv:2611.04200v1 cs.CV

Impact of Input Resolution in Mammographic Mass Detection: A Controlled Multi-Architecture Study

Kaan Buyukdemirci, Emine Ulku Saritas

제출 2026-11-04

원문 초록

Deep-learning-based mass detectors usually downsample mammograms, trading fine image detail for lower computational cost. However, published studies cannot reveal how much accuracy this trade-off sacrifices, since they also differ in architecture, preprocessing, and evaluation protocol. In this work, we isolated the effect of input resolution in a controlled study on the VinDr-Mammo dataset, training 18 detectors at six input resolutions ranging from 512 x 416 to 1600 x 1280 pixels, for 108 model-resolution combinations. Whole mammograms were resized without cropping or tiling. For each model, preprocessing, model initialization, augmentation, and evaluation procedures were kept fixed across resolutions. Detection accuracy was evaluated by mAP50 on the 219 mass-positive images of the official test split, and 57 combinations with test mAP50 of at least 0.60 were analyzed. From the lowest to the highest resolution, median mAP50 rose from 0.626 to 0.660 and the best mAP50 from 0.670 to 0.709. The best result, achieved by DINO with a ConvNeXt-S backbone, is the highest mAP50 reported to date on mass-positive VinDr-Mammo images. Gains were concentrated in small masses: for the smallest third of lesions, median mAP50 rose by 0.074 (from 0.367 to 0.441), compared with 0.007 and 0.032 for medium and large masses. Median training time increased from 0.45 to 1.40 h, and median inference time from 23.6 to 113.7 ms per image. Therefore, higher input resolution mainly benefits the small masses that are hardest to detect, at a computational cost that remains practical.

제출 이력

확인된 버전만 표시합니다. 전체 제출 이력은 arXiv 원문에서 확인하세요.

  1. arXiv:2611.04200v1제출 시각 미확인

함께 살펴볼 논문

공통 태그를 근거로 연결했습니다. 실제 인용 관계나 논문의 우수성을 뜻하지 않습니다.

공통 태그로 연결된 공개 논문이 아직 없습니다.

토론

이 논문과 연결된 포럼 글이 아직 없습니다.