Distortion-Corrected Diffusion MRI Using Rotated-View EPI and Joint Field-Map/Image Estimation with Gaussian Primitives
원문 초록
Echo planar imaging (EPI) is the standard acquisition technique for diffusion and functional neuroimaging, enabling rapid imaging but suffering from geometric distortions caused by B0 field inhomogeneities. Existing correction methods first reconstruct distorted images using parallel imaging, then estimate the B0 field and correct the distortion in the image domain. In this sequential process, reconstruction artifacts at high acceleration factors and low SNR at high diffusion b-values degrade B0 estimation and limit the overall correction quality. We propose a physics-informed framework that jointly estimates the B0 field, the distortion-free image, and the shot-to-shot phase directly from k-space data, without depending on an intermediate parallel-imaging reconstruction. All three are represented as superpositions of Gaussian primitives embedded within an EPI forward model; the explicit, continuous parameterization captures both smooth regions and tissue boundaries and is evaluated on rotated sampling grids without resampling. The diffusion-weighted image is modeled as real and non-negative, with the image phase absorbed into a per-shot phase factor. Acquiring the blip-up/blip-down data at several phase-encoding orientations, the rotated-view principle of PROPELLER applied to full-FOV single-shot EPI, distributes distortions across orientations, improving point spread function isotropy and providing stronger constraints for B0 estimation. On in vivo brain diffusion EPI at R=4 and 5, the proposed method attains the closest brain-boundary agreement with a distortion-free structural reference, with the largest improvement over sequential methods at high b-value.
제출 이력
확인된 버전만 표시합니다. 전체 제출 이력은 arXiv 원문에서 확인하세요.
- arXiv:2606.31521v2제출 시각 미확인
- arXiv:2606.31521v1제출 시각 미확인
함께 살펴볼 논문
공통 태그를 근거로 연결했습니다. 실제 인용 관계나 논문의 우수성을 뜻하지 않습니다.
공통 태그로 연결된 공개 논문이 아직 없습니다.
토론
이 논문과 연결된 포럼 글이 아직 없습니다.