Reliable Physiological Monitoring on the Wrist Using Generative Deep Learning to Address Poor Skin-Sensor Contact
원문 초록
Photoplethysmography (PPG) is a widely adopted, non-invasive technique for monitoring cardiovascular health and physiological parameters in both consumer and clinical settings. While motion artifacts in dynamic environments have been extensively studied, suboptimal skin-sensor contact in sedentary conditions - a critical yet underexplored issue - can distort PPG waveform morphology, leading to the loss or misalignment of key features and compromising sensing accuracy. In this work, we propose CP-PPG, a novel framework that transforms Contact Pressure-distorted PPG signals into high-fidelity waveforms with ideal morphology. CP-PPG integrates a custom data collection protocol, a carefully designed signal processing pipeline, and a novel deep adversarial model trained with a custom PPG-aware loss function. We validated CP-PPG through comprehensive evaluations, including 1) morphology transformation performance on our self-collected dataset, 2) downstream physiological monitoring performance on public datasets, and 3) in-the-wild study. Extensive experiments demonstrate substantial and consistent improvements in signal fidelity (Mean Absolute Error: 0.09, 40% improvement over the original signal) as well as downstream performance across all evaluations in Heart Rate (HR), Heart Rate Variability (HRV), Respiration Rate (RR), and Blood Pressure (BP) estimation (on average, 21% improvement in HR; 41-46% in HRV; 6% in RR; and 4-5% in BP). These findings highlight the critical importance of addressing skin-sensor contact issues to enhance the reliability and effectiveness of PPG-based physiological monitoring. CP-PPG thus holds significant potential to improve the accuracy of wearable health technologies in clinical and consumer applications.
함께 살펴볼 논문
공통 태그를 근거로 연결했습니다. 실제 인용 관계나 논문의 우수성을 뜻하지 않습니다.
Facial Video-based Remote Physiological Measurement via Self-supervised Learning
TAU: Modeling Temporal Consistency Through Temporal Attentive U-Net for PPG Peak Detection
Tri-Spectral PPG: Robust Reflective Photoplethysmography by Fusing Multiple Wavelengths for Cardiac Monitoring
Wearable Accelerometer Foundation Models for Health via Knowledge Distillation
PhysioZoo: The Open Digital Physiological Biomarkers Resource
A Self-Supervised Algorithm for Denoising Photoplethysmography Signals for Heart Rate Estimation from Wearables
토론
이 논문과 연결된 포럼 글이 아직 없습니다.