EAP4EMSIG -- Enhancing Event-Driven Microscopy for Microfluidic Single-Cell Analysis
원문 초록
Microfluidic Live-Cell Imaging yields data on microbial cell factories. However, continuous acquisition is challenging as high-throughput experiments often lack realtime insights, delaying responses to stochastic events. We introduce three components in the Experiment Automation Pipeline for Event-Driven Microscopy to Smart Microfluidic Single-Cell Analysis: a fast, accurate Deep Learning autofocusing method predicting the focus offset, an evaluation of real-time segmentation methods and a realtime data analysis dashboard. Our autofocusing achieves a Mean Absolute Error of 0.0226\textmu m with inference times below 50~ms. Among eleven Deep Learning segmentation methods, Cellpose~3 reached a Panoptic Quality of 93.58\%, while a distance-based method is fastest (121~ms, Panoptic Quality 93.02\%). All six Deep Learning Foundation Models were unsuitable for real-time segmentation.
함께 살펴볼 논문
공통 태그를 근거로 연결했습니다. 실제 인용 관계나 논문의 우수성을 뜻하지 않습니다.
Alleviating Textual Reliance in Medical Language-guided Segmentation via Prototype-driven Semantic Approximation
A New Dataset and Performance Benchmark for Real-time Spacecraft Segmentation in Onboard Flight Computers
Seg-Wild: Interactive Segmentation based on 3D Gaussian Splatting for Unconstrained Image Collections
PSAT: Pediatric Segmentation Approaches via Adult Augmentations and Transfer Learning
RSRefSeg 2: Decoupling Referring Remote Sensing Image Segmentation with Foundation Models
Learning Disentangled Stain and Structural Representations for Semi-Supervised Histopathology Segmentation
토론
이 논문과 연결된 포럼 글이 아직 없습니다.