Improving Neonatal Care: An Active Dry-Contact Electrode-based Continuous EEG Monitoring System with Seizure Detection
원문 초록
Objective: Neonates are highly susceptible to seizures, which can have severe long-term consequences if undetected and left untreated. Early detection is crucial and typically requires continuous electroencephalography (EEG) monitoring in a hospital setting, which is costly, inconvenient, and requires specialized experts for diagnosis. In this work, we propose a new low-cost active dry-contact electrode-based adjustable EEG headset, a new explainable deep learning model to detect neonatal seizures, and an advanced signal processing algorithm to remove artifacts to address the key aspects that lead to the underdiagnosis of neonatal seizures. Methods: EEG signals are acquired through active electrodes and processed using a custom-designed analog front end (AFE) that filters and digitizes the captured EEG signals. The adjustable headset is designed using three-dimensional (3D) printing and laser cutting to fit a wide range of head sizes. A deep learning model is developed to classify seizure and non-seizure epochs in real-time. Furthermore, a separate multimodal deep learning model is designed to remove noise artifacts. The device is tested on a pediatric patient with absence seizures in a hospital setting. Simultaneous recordings are captured using both the custom device and the commercial wet electrode device available in the hospital for comparison. Results: The signals obtained using our custom design and a commercial device show a high correlation (>0.8). Further analysis using signal-to-noise ratio values shows that our device can mitigate noise similar to the commercial device. The proposed deep learning model has improvements in accuracy and recall by 2.76% and 16.33%, respectively, compared to the state-of-the-art. Furthermore, the developed artifact removal algorithm can identify and remove artifacts while keeping seizure patterns intact.
함께 살펴볼 논문
공통 태그를 근거로 연결했습니다. 실제 인용 관계나 논문의 우수성을 뜻하지 않습니다.
DBConformer: Dual-Branch Convolutional Transformer for EEG Decoding
SeizureTransformer: Scaling U-Net with Transformer for Simultaneous Time-Step Level Seizure Detection from Long EEG Recordings
The Case for Cleaner Biosignals: High-fidelity Neural Compressor Enables Transfer from Cleaner iEEG to Noisier EEG
EEG-Based Inter-Patient Epileptic Seizure Detection Combining Domain Adversarial Training with CNN-BiLSTM Network
SzCORE as a benchmark: report from the seizure detection challenge at the 2025 AI in Epilepsy and Neurological Disorders Conference
The use of Multi-domain Electroencephalogram Representations in the building of Models based on Convolutional and Recurrent Neural Networks for Epilepsy Detection
토론
이 논문과 연결된 포럼 글이 아직 없습니다.