Computed tomography using meta-optics
원문 초록
Computer vision tasks require processing large amounts of data to perform image classification, segmentation, and feature extraction. Optical preprocessors can potentially reduce the number of floating point operations required by computer vision tasks, enabling low-power and low-latency operation. However, existing optical preprocessors are mostly learned and hence strongly depend on the training data, and thus lack universal applicability. In this paper, we present a metaoptic imager, which implements the Radon transform obviating the need for training the optics. High quality image reconstruction with a large compression ratio of 0.6% is presented through the use of the Simultaneous Algebraic Reconstruction Technique. Image classification with 90% accuracy is presented on an experimentally measured Radon dataset through neural network trained on digitally transformed images.
함께 살펴볼 논문
공통 태그를 근거로 연결했습니다. 실제 인용 관계나 논문의 우수성을 뜻하지 않습니다.
Hashed Watermark as a Filter: Defeating Forging and Overwriting Attacks in Weight-based Neural Network Watermarking
ViT-ProtoNet for Few-Shot Image Classification: A Multi-Benchmark Evaluation
MVNet: Hyperspectral Remote Sensing Image Classification Based on Hybrid Mamba-Transformer Vision Backbone Architecture
Beyond Accuracy: Metrics that Uncover What Makes a 'Good' Visual Descriptor
Linear Attention with Global Context: A Multipole Attention Mechanism for Vision and Physics
Revisiting CroPA: A Reproducibility Study and Enhancements for Cross-Prompt Adversarial Transferability in Vision-Language Models
토론
이 논문과 연결된 포럼 글이 아직 없습니다.