Accelerated Real-time Cine and Flow under In-magnet Staged Exercise
원문 초록
Background: Cardiovascular magnetic resonance imaging (CMR) is a well established imaging tool for diagnosing and managing cardiac conditions. The integration of exercise stress with CMR (ExCMR) can enhance its diagnostic capacity. Despite recent advances in CMR technology, quantitative ExCMR during exercise remains technically challenging due to motion artifacts and limited spatial and temporal resolution. Methods: This study investigated the feasibility of biventricular functional and hemodynamic assessment using real-time (RT) ExCMR during a staged exercise protocol in 24 healthy volunteers. We employed high acceleration rates and applied a coil reweighting technique to minimize motion blurring and artifacts. We further applied a beat-selection technique that identified beats from the endexpiratory phase to minimize the impact of respiration-induced through-plane motion on cardiac function quantification. Additionally, results from six patients were presented to demonstrate clinical feasibility. Results: Our findings indicated a consistent decrease in end-systolic volume and stable end-diastolic volume across exercise intensities, leading to increased stroke volume and ejection fraction. The selection of end-expiratory beats modestly enhanced the repeatability of cardiac function parameters, as shown by scan-rescan tests in nine volunteers. High scores from a blinded image quality assessment indicated that coil reweighting effectively minimized motion artifacts. Conclusions: This study demonstrated the feasibility of RT ExCMR with inmagnet exercise in healthy subjects and patients. Our results indicate that high acceleration rates, coil reweighting, and selection of respiratory phase-specific heartbeats enhance image quality and repeatability of quantitative RT ExCMR.
함께 살펴볼 논문
공통 태그를 근거로 연결했습니다. 실제 인용 관계나 논문의 우수성을 뜻하지 않습니다.
MS-IQA: A Multi-Scale Feature Fusion Network for PET/CT Image Quality Assessment
FundaQ-8: A Clinically-Inspired Scoring Framework for Automated Fundus Image Quality Assessment
A Cytology Dataset for Early Detection of Oral Squamous Cell Carcinoma
Text-Visual Semantic Constrained AI-Generated Image Quality Assessment
AI-Enhanced Pediatric Pneumonia Detection: A CNN-Based Approach Using Data Augmentation and Generative Adversarial Networks (GANs)
LangMamba: A Language-driven Mamba Framework for Low-dose CT Denoising with Vision-language Models
토론
이 논문과 연결된 포럼 글이 아직 없습니다.