A high performance active noise control system for magnetic fields
원문 초록
We present a system for active noise control (ANC) of environmental magnetic fields based on a Filtered-x Least Mean Squares (FxLMS) algorithm. The system consists of a sensor that detects the ambient field noise and an error sensor that measures the signal of interest contaminated with the noise. These signals are fed to an adaptive algorithm that constructs a physical anti-noise signal cancelling the local magnetic field noise. The proposed system achieves a maximum of 35 dB root-mean-square (RMS) noise suppression in the DC-1 kHz band and 50 dB and 40 dB amplitude suppression of 50 Hz and 150 Hz AC line noise respectively for all three axial directions of the magnetic vector field.
함께 살펴볼 논문
공통 태그를 근거로 연결했습니다. 실제 인용 관계나 논문의 우수성을 뜻하지 않습니다.
Scaling Laws of Dynamic High-Capacity Ride-Sharing
CUTS+: High-dimensional Causal Discovery from Irregular Time-series
CosmoPower-JAX: high-dimensional Bayesian inference with differentiable cosmological emulators
HumanRF: High-Fidelity Neural Radiance Fields for Humans in Motion
MIReAD: Simple Method for Learning High-quality Representations from Scientific Documents
High-Fidelity 3D Face Generation from Natural Language Descriptions
토론
이 논문과 연결된 포럼 글이 아직 없습니다.