arXiv:2104.07427

Estimation of atrial fibrillation from lead-I ECGs: Comparison with cardiologists and machine learning model (CurAlive), a clinical validation study

N. Korucuk, C. Polat, E. S. Gunduz, O. Karaman, V. Tosun, M. Onac, N. Yildirim, Y. Cete, K. Polat

제출 2021-04-15

원문 초록

Electrocardiogram recognition of cardiac arrhythmias is critical for cardiac abnormality diagnosis. Because of their strong prediction characteristics, artificial neural networks are the preferred method in medical diagnosis systems. This study presents a method to detect atrial fibrillation with lead-I ECGs using artificial intelligence. The aim of the study is to compare the accuracy of the diagnoses estimated by cardiologists and artificial intelligence over lead-I ECGs using 12-lead ECGs as references. To evaluate the performance of the proposed model, dataset were collected from China Physiological Signal Challenge 2018. In the study, diagnoses were examined in three groups as normal sinus rhythm, atrial fibrillation and OTHER. All rhythm and beat types except NSR and AFIB were labeled as OTHER super-class. OTHER contains First-degree atrioventricular blocks, Conduction disturbances, Left bundle branch block, Right bundle branch block, Premature atrial contraction, Premature ventricular contraction, ST-segment depression and ST-segment elevated type ECGs. CurAlive A.I. model which is using DenseNet as a CNN architecture and continuous wavelet transform as feature extraction method, showed a great performance on classifying ECGs from only lead-I compared to cardiologists. The AI model reached the weighted average precision, recall, F1-score and total accuracy 94.1%, 93.6%, 93.7% and 93.6% respectively, and the average of each of the three cardiologists has reached weighted average precision, recall, F1-score and total accuracy 82.2%, 54.6%, 57.5% and 54.6% respectively. This study showed that the proposed CNN model CurAlive, can be used to accurately diagnose AFIB, NSR, and OTHER rhythm using lead-I ECGs to accelerate the early detection of AFIB as a cardiologist assistant. It is also able to identify patients into different risk groups as part of remote patient monitoring systems.

함께 살펴볼 논문

공통 태그를 근거로 연결했습니다. 실제 인용 관계나 논문의 우수성을 뜻하지 않습니다.

arXiv:2502.02097v4cs.CV공통 태그 Medical Diagnosis공식 코드 · Papers with Code

VerteNet -- 측면 척추 DXA 영상에서 정확한 척추 랜드마크 위치 추정을 위한 다중 컨텍스트 하이브리드 CNN 트랜스포머

VerteNet -- A Multi-Context Hybrid CNN Transformer for Accurate Vertebral Landmark Localization in Lateral Spine DXA Images

이중에너지 X선 흡수계측법(Dual-Energy X-ray Absorptiometry, DXA) 기반 측면 척추 영상에서의 척추 랜드마크 위치 추정(Vertebral Landmarks Localization, VLL)은 척추 정렬 평가, 척추 골절 평가(Vertebral Fracture Assessment), 복부 대동맥 석회화(Abdominal Aortic Calcification) 정량화를 위한 추간 가이드 배치에 핵심적인 역할을 한다. 측면 척추 DXA 스캔은 비용 절감 및 낮은 방사선 노출이라는 장점을 제공하지만, 낮은 신호 대 잡음비와 영상 아티팩트로 인해 분석이 어렵다. 인공지능(AI)은 VLL의 정밀도와 정확도를 향상시키는 유망한 접근법으로 주목받고 있다. 본 연구에서는 세밀한 지역적 세부 정보와 광범위한 컨텍스트 정보를 모두 포착하기 위해 이중 해상도 어텐션 메커니즘을 적용한 새로운 아키텍처를 제안한다. 제안된 방법은 이중 해상도 자기 어텐션(self-attention) 및 교차 어텐션(cross-attention) 메커니즘을 통해 스킵 연결(skip connection)과 디코더 레이어를 활용함으로써 특징 통합을 강화한다. 이러한 설계는 모델이 복잡한 패턴을 학습하는 능력을 향상시켜 지역적 및 전역적 컨텍스트 인식을 유지하면서 정확한 척추 코너 위치 추정을 가능하게 한다. 제안된 프레임워크를 다수의 장비로 획득한 DXA 측면 척추 영상(LSI)에서 평가한 결과, VLL에서 최신 최첨단 아키텍처를 능가하여 정규화 평균 오차 4.92, 정규화 중앙값 오차 2.35를 달성하였다. 제안된 프레임워크인 VerteNet은 다양한 촬영 시스템의 DXA LSI 영상에서 높은 정확도의 VLL을 가능하게 하며, 세밀한 지역적 세부 정보와 광범위한 컨텍스트 정보를 모두 포착하는 향상된 능력 덕분에 낮은 신호 대 잡음비에 대한 강한 강건성을 보인다.

토론

이 논문과 연결된 포럼 글이 아직 없습니다.