arXiv:2104.02042

Automated lung segmentation from CT images of normal and COVID-19 pneumonia patients

Faeze Gholamiankhah, Samaneh Mostafapour, Nouraddin Abdi Goushbolagh, Seyedjafar Shojaerazavi, Parvaneh Layegh, Seyyed Mohammad Tabatabaei, Hossein Arabi

제출 2021-04-05

원문 초록

Automated semantic image segmentation is an essential step in quantitative image analysis and disease diagnosis. This study investigates the performance of a deep learning-based model for lung segmentation from CT images for normal and COVID-19 patients. Chest CT images and corresponding lung masks of 1200 confirmed COVID-19 cases were used for training a residual neural network. The reference lung masks were generated through semi-automated/manual segmentation of the CT images. The performance of the model was evaluated on two distinct external test datasets including 120 normal and COVID-19 subjects, and the results of these groups were compared to each other. Different evaluation metrics such as dice coefficient (DSC), mean absolute error (MAE), relative mean HU difference, and relative volume difference were calculated to assess the accuracy of the predicted lung masks. The proposed deep learning method achieved DSC of 0.980 and 0.971 for normal and COVID-19 subjects, respectively, demonstrating significant overlap between predicted and reference lung masks. Moreover, MAEs of 0.037 HU and 0.061 HU, relative mean HU difference of -2.679% and -4.403%, and relative volume difference of 2.405% and 5.928% were obtained for normal and COVID-19 subjects, respectively. The comparable performance in lung segmentation of the normal and COVID-19 patients indicates the accuracy of the model for the identification of the lung tissue in the presence of the COVID-19 induced infections (though slightly better performance was observed for normal patients). The promising results achieved by the proposed deep learning-based model demonstrated its reliability in COVID-19 lung segmentation. This prerequisite step would lead to a more efficient and robust pneumonia lesion analysis.

함께 살펴볼 논문

공통 태그를 근거로 연결했습니다. 실제 인용 관계나 논문의 우수성을 뜻하지 않습니다.

arXiv:2607.20326v1cs.CV공통 태그 Image Segmentation, Segmentation, Semantic Segmentation

신뢰할 수 있는 RGB-D 의미 분할을 햽하여: Condition Dropout을 통한 결측 모달리티 처리

Toward Reliable RGB-D Semantic Segmentation: Handling Missing Modalities via Condition Dropout

RGB-D 의미 분할은 눈에 띄는 진전을 이루었지만, 대부분의 모델은 RGB와 깊이(depth)가 항상 사용 가능하다고 가정한다. 실제로는 감시 센서의 고장이나 가림(occlusion)으로 인해 한쪽 모달리티가 사라지는 경우가 많다. RGB 또는 깊이만으로도 충분한 단서를 담을 수 있지만, 전체 모달리티 입력만으로 학습된 모델은 한쪽 모달리티가 없어지면 남은 모달리티를 활용하지 못해 성능이 크게 저하된다. 우리는 이 문제를 간단한 지속 학습(continued training) 패러다임인 Condition Dropout(ConD)으로 해결한다. ConD는 전체 모달리티 정확도를 유지하면서 성능 저하를 완화한다. 사전학습된 RGB-D 모델에서 출발하여, ConD는 두 번째 단계를 추가한다. 이 단계에서는 완전한 입력, RGB 결측 입력, 깊이 결측 입력을 무작위로 시뮬레이션하고, 원래 인코더를 고정(freeze)한 뒤, 복사한 인코더를 영-초기화(zero-initialized) 특징(feature) 주입과 함께 학습한다. NYU-Depth V2와 SUN RGB-D에서의 실험은 ConD가 결측 모달리티 상황에서 견고성(robustness)을 향상시키며, 모달리티가 모두 있을 때에도 약간의 성능 향상을 보인다는 것을 보여준다. 우리 코드는 논문 채택 시 공개될 예정이다.

토론

이 논문과 연결된 포럼 글이 아직 없습니다.