Most advances in medical image recognition supporting clinical auxiliary diagnosis meet challenges due to the low-resource situation in the medical field, where annotations are highly expensive and professional. This low-resource problem can be alleviated by leveraging the transferable representations of large-scale pre-trained vision-language models via relevant medical text prompts. However, existing pre-trained vision-language models require domain experts to carefully design the medical prompts, which greatly increases the burden on clinicians. To address this problem, we propose a weakly supervised prompt learning method MedPrompt to automatically generate medical prompts, which includes an unsupervised pre-trained vision-language model and a weakly supervised prompt learning model. The unsupervised pre-trained vision-language model utilizes the natural correlation between medical images and corresponding medical texts for pre-training, without any manual annotations. The weakly supervised prompt learning model only utilizes the classes of images in the dataset to guide the learning of the specific class vector in the prompt, while the learning of other context vectors in the prompt requires no manual annotations for guidance. To the best of our knowledge, this is the first model to automatically generate medical prompts. With these prompts, the pre-trained vision-language model can be freed from the strong expert dependency of manual annotation and manual prompt design. Experimental results show that the model using our automatically generated prompts outperforms its full-shot learning hand-crafted prompts counterparts with only a minimal number of labeled samples for few-shot learning, and reaches superior or comparable accuracy on zero-shot image classification. The proposed prompt generator is lightweight and therefore can be embedded into any network architecture.
Initial weighting is significant in deep neural networks because the random selection of weights produces different outputs and increases the probability of overfitting and underfitting. On the other hand, vector-based approaches to extract vector features need rich vectors for more accurate classification. The InceptionCapsule approach is presented to alleviate these two problems. This approach uses transfer learning and the Inception-ResNet model to avoid random selection of weights, which takes initial weights from ImageNet. It also uses the output of Inception middle layers to generate rich vectors. Extracted vectors are given to a capsule network for learning, which is equipped with an attention technique. Kvasir data and BUSI with the GT dataset were used to evaluate this approach. This model was able to achieve 97.62 accuracies in 5-class classification and also achieved 94.30 accuracies in 8-class classification on Kvasir. In the BUSI with GT dataset, the proposed approach achieved accuracy=98.88, Precision=95.34, and F1-score=93.74, which are acceptable results compared to other approaches in the literature.
Rapid development of disease detection computer vision models is vital in response to urgent medical crises like epidemics or events of bioterrorism. However, traditional data gathering methods are too slow for these scenarios necessitating innovative approaches to generate reliable models quickly from minimal data. We demonstrate our new approach by building a comprehensive computer vision model for detecting Human Papilloma Virus Genital warts using only synthetic data. In our study, we employed a two phase experimental design using diffusion models. In the first phase diffusion models were utilized to generate a large number of diverse synthetic images from 10 HPV guide images explicitly focusing on accurately depicting genital warts. The second phase involved the training and testing vision model using this synthetic dataset. This method aimed to assess the effectiveness of diffusion models in rapidly generating high quality training data and the subsequent impact on the vision model performance in medical image recognition. The study findings revealed significant insights into the performance of the vision model trained on synthetic images generated through diffusion models. The vision model showed exceptional performance in accurately identifying cases of genital warts. It achieved an accuracy rate of 96% underscoring its effectiveness in medical image classification. For HPV cases the model demonstrated a high precision of 99% and a recall of 94%. In normal cases the precision was 95% with an impressive recall of 99%. These metrics indicate the model capability to correctly identify true positive cases and minimize false positives. The model achieved an F1 Score of 96% for HPV cases and 97% for normal cases. The high F1 Score across both categories highlights the balanced nature of the model precision and recall ensuring reliability and robustness in its predictions.
Image classifiers for domain-specific tasks like Synthetic Aperture Radar Automatic Target Recognition (SAR ATR) and chest X-ray classification often rely on convolutional neural networks (CNNs). These networks, while powerful, experience high latency due to the number of operations they perform, which can be problematic in real-time applications. Many image classification models are designed to work with both RGB and grayscale datasets, but classifiers that operate solely on grayscale images are less common. Grayscale image classification has critical applications in fields such as medical imaging and SAR ATR. In response, we present a novel grayscale image classification approach using a vectorized view of images. By leveraging the lightweight nature of Multi-Layer Perceptrons (MLPs), we treat images as vectors, simplifying the problem to grayscale image classification. Our approach incorporates a single graph convolutional layer in a batch-wise manner, enhancing accuracy and reducing performance variance. Additionally, we develop a customized accelerator on FPGA for our model, incorporating several optimizations to improve performance. Experimental results on benchmark grayscale image datasets demonstrate the effectiveness of our approach, achieving significantly lower latency (up to $16\times$ less on MSTAR) and competitive or superior performance compared to state-of-the-art models for SAR ATR and medical image classification.
Using deep learning models pre-trained on Imagenet is the traditional solution for medical image classification to deal with data scarcity. Nevertheless, relevant literature supports that this strategy may offer limited gains due to the high dissimilarity between domains. Currently, the paradigm of adapting domain-specialized foundation models is proving to be a promising alternative. However, how to perform such knowledge transfer, and the benefits and limitations it presents, are under study. The CGI-HRDC challenge for Hypertensive Retinopathy diagnosis on fundus images introduces an appealing opportunity to evaluate the transferability of a recently released vision-language foundation model of the retina, FLAIR. In this work, we explore the potential of using FLAIR features as starting point for fundus image classification, and we compare its performance with regard to Imagenet initialization on two popular transfer learning methods: Linear Probing (LP) and Fine-Tuning (FP). Our empirical observations suggest that, in any case, the use of the traditional strategy provides performance gains. In contrast, direct transferability from FLAIR model allows gains of 2.5%. When fine-tuning the whole network, the performance gap increases up to 4%. In this case, we show that avoiding feature deterioration via LP initialization of the classifier allows the best re-use of the rich pre-trained features. Although direct transferability using LP still offers limited performance, we believe that foundation models such as FLAIR will drive the evolution of deep-learning-based fundus image analysis.
Deep learning could be prone to learning shortcuts raised by dataset bias and result in inaccurate, unreliable, and unfair models, which impedes its adoption in real-world clinical applications. Despite its significance, there is a dearth of research in the medical image classification domain to address dataset bias. Furthermore, the bias labels are often agnostic, as identifying biases can be laborious and depend on post-hoc interpretation. This paper proposes learning Adaptive Agreement from a Biased Council (Ada-ABC), a debiasing framework that does not rely on explicit bias labels to tackle dataset bias in medical images. Ada-ABC develops a biased council consisting of multiple classifiers optimized with generalized cross entropy loss to learn the dataset bias. A debiasing model is then simultaneously trained under the guidance of the biased council. Specifically, the debiasing model is required to learn adaptive agreement with the biased council by agreeing on the correctly predicted samples and disagreeing on the wrongly predicted samples by the biased council. In this way, the debiasing model could learn the target attribute on the samples without spurious correlations while also avoiding ignoring the rich information in samples with spurious correlations. We theoretically demonstrated that the debiasing model could learn the target features when the biased model successfully captures dataset bias. Moreover, to our best knowledge, we constructed the first medical debiasing benchmark from four datasets containing seven different bias scenarios. Our extensive experiments practically showed that our proposed Ada-ABC outperformed competitive approaches, verifying its effectiveness in mitigating dataset bias for medical image classification. The codes and organized benchmark datasets will be made publicly available.
Medical image segmentation aims to identify and locate abnormal structures in medical images, such as chest radiographs, using deep neural networks. These networks require a large number of annotated images with fine-grained masks for the regions of interest, making pre-training strategies based on classification datasets essential for sample efficiency. Based on a large-scale medical image classification dataset, our work collects explanations from well-trained classifiers to generate pseudo labels of segmentation tasks. Specifically, we offer a case study on chest radiographs and train image classifiers on the CheXpert dataset to identify 14 pathological observations in radiology. We then use Integrated Gradients (IG) method to distill and boost the explanations obtained from the classifiers, generating massive diagnosis-oriented localization labels (DoLL). These DoLL-annotated images are used for pre-training the model before fine-tuning it for downstream segmentation tasks, including COVID-19 infectious areas, lungs, heart, and clavicles. Our method outperforms other baselines, showcasing significant advantages in model performance and training efficiency across various segmentation settings.
Noisy labels can significantly impact medical image classification, particularly in deep learning, by corrupting learned features. Self-supervised pretraining, which doesn't rely on labeled data, can enhance robustness against noisy labels. However, this robustness varies based on factors like the number of classes, dataset complexity, and training size. In medical images, subtle inter-class differences and modality-specific characteristics add complexity. Previous research hasn't comprehensively explored the interplay between self-supervised learning and robustness against noisy labels in medical image classification, considering all these factors. In this study, we address three key questions: i) How does label noise impact various medical image classification datasets? ii) Which types of medical image datasets are more challenging to learn and more affected by label noise? iii) How do different self-supervised pretraining methods enhance robustness across various medical image datasets? Our results show that DermNet, among five datasets (Fetal plane, DermNet, COVID-DU-Ex, MURA, NCT-CRC-HE-100K), is the most challenging but exhibits greater robustness against noisy labels. Additionally, contrastive learning stands out among the eight self-supervised methods as the most effective approach to enhance robustness against noisy labels.
Deep learning models for medical image analysis easily suffer from distribution shifts caused by dataset artifacts bias, camera variations, differences in the imaging station, etc., leading to unreliable diagnoses in real-world clinical settings. Domain generalization (DG) methods, which aim to train models on multiple domains to perform well on unseen domains, offer a promising direction to solve the problem. However, existing DG methods assume domain labels of each image are available and accurate, which is typically feasible for only a limited number of medical datasets. To address these challenges, we propose a novel DG framework for medical image classification without relying on domain labels, called Prompt-driven Latent Domain Generalization (PLDG). PLDG consists of unsupervised domain discovery and prompt learning. This framework first discovers pseudo domain labels by clustering the bias-associated style features, then leverages collaborative domain prompts to guide a Vision Transformer to learn knowledge from discovered diverse domains. To facilitate cross-domain knowledge learning between different prompts, we introduce a domain prompt generator that enables knowledge sharing between domain prompts and a shared prompt. A domain mixup strategy is additionally employed for more flexible decision margins and mitigates the risk of incorrect domain assignments. Extensive experiments on three medical image classification tasks and one debiasing task demonstrate that our method can achieve comparable or even superior performance than conventional DG algorithms without relying on domain labels. Our code will be publicly available upon the paper is accepted.
Early cancer detection is crucial for prognosis, but many cancer types lack large labelled datasets required for developing deep learning models. This paper investigates self-supervised learning (SSL) as an alternative to the standard supervised pre-training on ImageNet for scenarios with limited training data using a deep learning model (ResNet-50). We first demonstrate that SSL pre-training on ImageNet (via the Barlow Twins SSL algorithm) outperforms supervised pre-training (SL) using a skin lesion dataset with limited training samples. We then consider \textit{further} SSL pre-training (of the two ImageNet pre-trained models) on task-specific datasets, where our implementation is motivated by supervised transfer learning. This approach significantly enhances initially SL pre-trained models, closing the performance gap with initially SSL pre-trained ones. Surprisingly, further pre-training on just the limited fine-tuning data achieves this performance equivalence. Linear probe experiments reveal that improvement stems from enhanced feature extraction. Hence, we find that minimal further SSL pre-training on task-specific data can be as effective as large-scale SSL pre-training on ImageNet for medical image classification tasks with limited labelled data. We validate these results on an oral cancer histopathology dataset, suggesting broader applicability across medical imaging domains facing labelled data scarcity.
Modern healthcare often utilises radiographic images alongside textual reports for diagnostics, encouraging the use of Vision-Language Self-Supervised Learning (VL-SSL) with large pre-trained models to learn versatile medical vision representations. However, most existing VL-SSL frameworks are trained end-to-end, which is computation-heavy and can lose vital prior information embedded in pre-trained encoders. To address both issues, we introduce the backbone-agnostic Adaptor framework, which preserves medical knowledge in pre-trained image and text encoders by keeping them frozen, and employs a lightweight Adaptor module for cross-modal learning. Experiments on medical image classification and segmentation tasks across three datasets reveal that our framework delivers competitive performance while cutting trainable parameters by over 90% compared to current pre-training approaches. Notably, when fine-tuned with just 1% of data, Adaptor outperforms several Transformer-based methods trained on full datasets in medical image segmentation.
In the field of medical image analysis, deep learning models have demonstrated remarkable success in enhancing diagnostic accuracy and efficiency. However, the reliability of these models is heavily dependent on the quality of training data, and the existence of label noise (errors in dataset annotations) of medical image data presents a significant challenge. This paper introduces a new sample selection method that enhances the performance of neural networks when trained on noisy datasets. Our approach features estimating the noise rate of a dataset by analyzing the distribution of loss values using Linear Regression. Samples are then ranked according to their loss values, and potentially noisy samples are excluded from the dataset. Additionally, we employ sparse regularization to further enhance the noise robustness of our model. Our proposed method is evaluated on five benchmark datasets and a real-life noisy medical image dataset. Notably, two of these datasets contain 3D medical images. The results of our experiments show that our method outperforms existing noise-robust learning methods, particularly in scenarios with high noise rates. Key words: noise-robust learning, medical image analysis, noise rate estimation, sample selection, sparse regularization
Recent advancements in foundation models, typically trained with self-supervised learning on large-scale and diverse datasets, have shown great potential in medical image analysis. However, due to the significant spatial heterogeneity of medical imaging data, current models must tailor specific structures for different datasets, making it challenging to leverage the abundant unlabeled data. In this work, we propose a universal foundation model for medical image analysis that processes images with heterogeneous spatial properties using a unified structure. To accomplish this, we propose spatially adaptive networks (SPAD-Nets), a family of networks that dynamically adjust the structures to adapt to the spatial properties of input images, to build such a universal foundation model. We pre-train a spatial adaptive visual tokenizer (SPAD-VT) and then a spatial adaptive Vision Transformer (SPAD-ViT) via masked image modeling (MIM) on 55 public medical image datasets. The pre-training data comprises over 9 million image slices, representing the largest, most comprehensive, and most diverse dataset to our knowledge for pre-training universal foundation models for medical image analysis. The experimental results on downstream medical image classification and segmentation tasks demonstrate the superior performance and label efficiency of our model. Our code is available at https://github.com/function2-llx/PUMIT.
Dementia is one of the most common diseases in the elderly and a leading cause of mortality and disability. In recent years, a research effort has been made to develop computer aided diagnosis tools based on machine (deep) learning models fed with neuroimaging data. However, while much work has been done on MRI imaging, very little attention has been paid on amyloid PETs, which have been recently recognized to be a promising and powerful biomarker of neurodegeneration. In this paper, we contribute to this less explored research area by proposing a 3D Convolutional Neural Network aimed at detecting dementia based on amyloid PET scans. An experiment performed on the recently released OASIS-3 dataset, which provides the community with a new benchmark to advance this line of research further, yielded very promising results and provided new evidence on the effectiveness of amyloid PET.
The Internet of Medical Things (IoMT) has dramatically benefited medical professionals that patients and physicians can access from all regions. Although the automatic detection and prediction of diseases such as melanoma and leukemia is still being researched and studied in IoMT, existing approaches are not able to achieve a high degree of efficiency. Thus, with a new approach that provides better results, patients would access the adequate treatments earlier and the death rate would be reduced. Therefore, this paper introduces an IoMT proposal for medical images classification that may be used anywhere, i.e. it is an ubiquitous approach. It was design in two stages: first, we employ a Transfer Learning (TL)-based method for feature extraction, which is carried out using MobileNetV3; second, we use the Chaos Game Optimization (CGO) for feature selection, with the aim of excluding unnecessary features and improving the performance, which is key in IoMT. Our methodology was evaluated using ISIC-2016, PH2, and Blood-Cell datasets. The experimental results indicated that the proposed approach obtained an accuracy of 88.39% on ISIC-2016, 97.52% on PH2, and 88.79% on Blood-cell. Moreover, our approach had successful performances for the metrics employed compared to other existing methods.
Modern deep neural networks have achieved great successes in medical image analysis. However, the features captured by convolutional neural networks (CNNs) or Transformers tend to be optimized for pixel intensities and neglect key anatomical structures such as connected components and loops. In this paper, we propose a persistent homology guided approach (PHG-Net) that explores topological features of objects for medical image classification. For an input image, we first compute its cubical persistence diagram and extract topological features into a vector representation using a small neural network (called the PH module). The extracted topological features are then incorporated into the feature map generated by CNN or Transformer for feature fusion. The PH module is lightweight and capable of integrating topological features into any CNN or Transformer architectures in an end-to-end fashion. We evaluate our PHG-Net on three public datasets and demonstrate its considerable improvements on the target classification tasks over state-of-the-art methods.
Computer-aided diagnosis of skin diseases is an important tool. However, the interpretability of computer-aided diagnosis is currently poor. Dermatologists and patients cannot intuitively understand the learning and prediction process of neural networks, which will lead to a decrease in the credibility of computer-aided diagnosis. In addition, traditional methods need to be trained using negative samples in order to predict the presence or absence of a lesion, but medical data is often in short supply. In this paper, we propose a multiple high-order attention interaction model (MHA-UNet) for use in a highly explainable skin lesion segmentation task. MHA-UNet is able to obtain the presence or absence of a lesion by explainable reasoning without the need for training on negative samples. Specifically, we propose a high-order attention interaction mechanism that introduces squeeze attention to a higher level for feature attention. In addition, a multiple high-order attention interaction (MHAblock) module is proposed by combining the different features of different orders. For classifying the presence or absence of lesions, we conducted classification experiments on several publicly available datasets in the absence of negative samples, based on explainable reasoning about the interaction of 5 attention orders of MHAblock. The highest positive detection rate obtained from the experiments was 81.0% and the highest negative detection rate was 83.5%. For segmentation experiments, comparison experiments of the proposed method with 13 medical segmentation models and external validation experiments with 8 state-of-the-art models in three public datasets and our clinical dataset demonstrate the state-of-the-art performance of our model. The code is available from https://github.com/wurenkai/MHA-UNet.
Although current data augmentation methods are successful to alleviate the data insufficiency, conventional augmentation are primarily intra-domain while advanced generative adversarial networks (GANs) generate images remaining uncertain, particularly in small-scale datasets. In this paper, we propose a parameterized GAN (ParaGAN) that effectively controls the changes of synthetic samples among domains and highlights the attention regions for downstream classification. Specifically, ParaGAN incorporates projection distance parameters in cyclic projection and projects the source images to the decision boundary to obtain the class-difference maps. Our experiments show that ParaGAN can consistently outperform the existing augmentation methods with explainable classification on two small-scale medical datasets.
Federated Learning (FL) is a collaborative training paradigm that allows for privacy-preserving learning of cross-institutional models by eliminating the exchange of sensitive data and instead relying on the exchange of model parameters between the clients and a server. Despite individual studies on how client models are aggregated, and, more recently, on the benefits of ImageNet pre-training, there is a lack of understanding of the effect the architecture chosen for the federation has, and of how the aforementioned elements interconnect. To this end, we conduct the first joint ARchitecture-Initialization-Aggregation study and benchmark ARIAs across a range of medical image classification tasks. We find that, contrary to current practices, ARIA elements have to be chosen together to achieve the best possible performance. Our results also shed light on good choices for each element depending on the task, the effect of normalisation layers, and the utility of SSL pre-training, pointing to potential directions for designing FL-specific architectures and training pipelines.
In recent years, the rapid development of deep learning has led to a wide range of applications in the field of medical image classification. The variants of neural network models with ever-increasing performance share some commonalities: to try to mitigate overfitting, improve generalization, avoid gradient vanishing and exploding, etc. AlexNet first utilizes the dropout technique to mitigate overfitting and the ReLU activation function to avoid gradient vanishing. Therefore, we focus our discussion on AlexNet, which has contributed greatly to the development of CNNs in 2012. After reviewing over 40 papers, including journal papers and conference papers, we give a narrative on the technical details, advantages, and application areas of AlexNet.