As the rapid development of computer vision and the emergence of powerful network backbones and architectures, the application of deep learning in medical imaging has become increasingly significant. Unlike natural images, medical images lack huge volumes of data but feature more modalities, making it difficult to train a general model that has satisfactory performance across various datasets. In practice, practitioners often suffer from manually creating and testing models combining independent backbones and architectures, which is a laborious and time-consuming process. We propose Flemme, a FLExible and Modular learning platform for MEdical images. Our platform separates encoders from the model architectures so that different models can be constructed via various combinations of supported encoders and architectures. We construct encoders using building blocks based on convolution, transformer, and state-space model (SSM) to process both 2D and 3D image patches. A base architecture is implemented following an encoder-decoder style, with several derived architectures for image segmentation, reconstruction, and generation tasks. In addition, we propose a general hierarchical architecture incorporating a pyramid loss to optimize and fuse vertical features. Experiments demonstrate that this simple design leads to an average improvement of 5.60% in Dice score and 7.81% in mean interaction of units (mIoU) for segmentation models, as well as an enhancement of 5.57% in peak signal-to-noise ratio (PSNR) and 8.22% in structural similarity (SSIM) for reconstruction models. We further utilize Flemme as an analytical tool to assess the effectiveness and efficiency of various encoders across different tasks. Code is available at https://github.com/wlsdzyzl/flemme.
Semantic segmentation is a significant perception task in autonomous driving. It suffers from the risks of adversarial examples. In the past few years, deep learning has gradually transitioned from convolutional neural network (CNN) models with a relatively small number of parameters to foundation models with a huge number of parameters. The segment-anything model (SAM) is a generalized image segmentation framework that is capable of handling various types of images and is able to recognize and segment arbitrary objects in an image without the need to train on a specific object. It is a unified model that can handle diverse downstream tasks, including semantic segmentation, object detection, and tracking. In the task of semantic segmentation for autonomous driving, it is significant to study the zero-shot adversarial robustness of SAM. Therefore, we deliver a systematic empirical study on the robustness of SAM without additional training. Based on the experimental results, the zero-shot adversarial robustness of the SAM under the black-box corruptions and white-box adversarial attacks is acceptable, even without the need for additional training. The finding of this study is insightful in that the gigantic model parameters and huge amounts of training data lead to the phenomenon of emergence, which builds a guarantee of adversarial robustness. SAM is a vision foundation model that can be regarded as an early prototype of an artificial general intelligence (AGI) pipeline. In such a pipeline, a unified model can handle diverse tasks. Therefore, this research not only inspects the impact of vision foundation models on safe autonomous driving but also provides a perspective on developing trustworthy AGI. The code is available at: https://github.com/momo1986/robust_sam_iv.
Brain tumor segmentation is often based on multiple magnetic resonance imaging (MRI). However, in clinical practice, certain modalities of MRI may be missing, which presents a more difficult scenario. To cope with this challenge, Knowledge Distillation, Domain Adaption, and Shared Latent Space have emerged as commonly promising strategies. However, recent efforts typically overlook the modality gaps and thus fail to learn important invariant feature representations across different modalities. Such drawback consequently leads to limited performance for missing modality models. To ameliorate these problems, pre-trained models are used in natural visual segmentation tasks to minimize the gaps. However, promising pre-trained models are often unavailable in medical image segmentation tasks. Along this line, in this paper, we propose a novel paradigm that aligns latent features of involved modalities to a well-defined distribution anchor as the substitution of the pre-trained model}. As a major contribution, we prove that our novel training paradigm ensures a tight evidence lower bound, thus theoretically certifying its effectiveness. Extensive experiments on different backbones validate that the proposed paradigm can enable invariant feature representations and produce models with narrowed modality gaps. Models with our alignment paradigm show their superior performance on both BraTS2018 and BraTS2020 datasets.
Image segmentation plays an important role in vision understanding. Recently, the emerging vision foundation models continuously achieved superior performance on various tasks. Following such success, in this paper, we prove that the Segment Anything Model 2 (SAM2) can be a strong encoder for U-shaped segmentation models. We propose a simple but effective framework, termed SAM2-UNet, for versatile image segmentation. Specifically, SAM2-UNet adopts the Hiera backbone of SAM2 as the encoder, while the decoder uses the classic U-shaped design. Additionally, adapters are inserted into the encoder to allow parameter-efficient fine-tuning. Preliminary experiments on various downstream tasks, such as camouflaged object detection, salient object detection, marine animal segmentation, mirror detection, and polyp segmentation, demonstrate that our SAM2-UNet can simply beat existing specialized state-of-the-art methods without bells and whistles. Project page: \url{https://github.com/WZH0120/SAM2-UNet}.
Medical image segmentation is crucial for clinical decision-making, but the scarcity of annotated data presents significant challenges. Few-shot segmentation (FSS) methods show promise but often require training on the target domain and struggle to generalize across different modalities. Similarly, adapting foundation models like the Segment Anything Model (SAM) for medical imaging has limitations, including the need for finetuning and domain-specific adaptation. To address these issues, we propose a novel method that adapts DINOv2 and Segment Anything Model 2 (SAM 2) for retrieval-augmented few-shot medical image segmentation. Our approach uses DINOv2's feature as query to retrieve similar samples from limited annotated data, which are then encoded as memories and stored in memory bank. With the memory attention mechanism of SAM 2, the model leverages these memories as conditions to generate accurate segmentation of the target image. We evaluated our framework on three medical image segmentation tasks, demonstrating superior performance and generalizability across various modalities without the need for any retraining or finetuning. Overall, this method offers a practical and effective solution for few-shot medical image segmentation and holds significant potential as a valuable annotation tool in clinical applications.
Ophthalmic image segmentation serves as a critical foundation for ocular disease diagnosis. Although fully convolutional neural networks (CNNs) are commonly employed for segmentation, they are constrained by inductive biases and face challenges in establishing long-range dependencies. Transformer-based models address these limitations but introduce substantial computational overhead. Recently, a simple yet efficient Multilayer Perceptron (MLP) architecture was proposed for image classification, achieving competitive performance relative to advanced transformers. However, its effectiveness for ophthalmic image segmentation remains unexplored. In this paper, we introduce MM-UNet, an efficient Mixed MLP model tailored for ophthalmic image segmentation. Within MM-UNet, we propose a multi-scale MLP (MMLP) module that facilitates the interaction of features at various depths through a grouping strategy, enabling simultaneous capture of global and local information. We conducted extensive experiments on both a private anterior segment optical coherence tomography (AS-OCT) image dataset and a public fundus image dataset. The results demonstrated the superiority of our MM-UNet model in comparison to state-of-the-art deep segmentation networks.
The Segment Anything Model (SAM), a foundational model designed for promptable segmentation tasks, demonstrates exceptional generalization capabilities, making it highly promising for natural scene image segmentation. However, SAM's lack of pretraining on massive remote sensing images and its interactive structure limit its automatic mask prediction capabilities. In this paper, a Multi-Cognitive SAM-Based Instance Segmentation Model (MC-SAM SEG) is introduced to employ SAM on remote sensing domain. The SAM-Mona encoder utilizing the Multi-cognitive Visual Adapter (Mona) is conducted to facilitate SAM's transfer learning in remote sensing applications. The proposed method named MC-SAM SEG extracts high-quality features by fine-tuning the SAM-Mona encoder along with a feature aggregator. Subsequently, a pixel decoder and transformer decoder are designed for prompt-free mask generation and instance classification. The comprehensive experiments are conducted on the HRSID and WHU datasets for instance segmentation tasks on Synthetic Aperture Radar (SAR) images and optical remote sensing images respectively. The evaluation results indicate the proposed method surpasses other deep learning algorithms and verify its effectiveness and generalization.
Cardiac segmentation is a critical task in medical imaging, essential for detailed analysis of heart structures, which is crucial for diagnosing and treating various cardiovascular diseases. With the advent of deep learning, automated segmentation techniques have demonstrated remarkable progress, achieving high accuracy and efficiency compared to traditional manual methods. Among these techniques, the nnU-Net framework stands out as a robust and versatile tool for medical image segmentation. In this study, we evaluate the performance of nnU-Net in segmenting cardiac magnetic resonance images (MRIs). Utilizing five cardiac segmentation datasets, we employ various nnU-Net configurations, including 2D, 3D full resolution, 3D low resolution, 3D cascade, and ensemble models. Our study benchmarks the capabilities of these configurations and examines the necessity of developing new models for specific cardiac segmentation tasks.
Recently, the state space model Mamba has demonstrated efficient long-sequence modeling capabilities, particularly for addressing long-sequence visual tasks in 3D medical imaging. However, existing generative self-supervised learning methods have not yet fully unleashed Mamba's potential for handling long-range dependencies because they overlook the inherent causal properties of state space sequences in masked modeling. To address this challenge, we propose a general-purpose pre-training framework called MambaMIM, a masked image modeling method based on a novel TOKen-Interpolation strategy (TOKI) for the selective structure state space sequence, which learns causal relationships of state space within the masked sequence. Further, MambaMIM introduces a bottom-up 3D hybrid masking strategy to maintain a masking consistency across different architectures and can be used on any single or hybrid Mamba architecture to enhance its multi-scale and long-range representation capability. We pre-train MambaMIM on a large-scale dataset of 6.8K CT scans and evaluate its performance across eight public medical segmentation benchmarks. Extensive downstream experiments reveal the feasibility and advancement of using Mamba for medical image pre-training. In particular, when we apply the MambaMIM to a customized architecture that hybridizes MedNeXt and Vision Mamba, we consistently obtain the state-of-the-art segmentation performance. The code is available at: https://github.com/FengheTan9/MambaMIM.
Deep learning based approaches are now widely used across biophysics to help automate a variety of tasks including image segmentation, feature selection, and deconvolution. However, the presence of multiple competing deep learning architectures, each with its own unique advantages and disadvantages, makes it challenging to select an architecture best suited for a specific application. As such, we present a comprehensive comparison of common models. Here, we focus on the task of segmentation assuming the typically small training dataset sizes available from biophysics experiments and compare the following four commonly used architectures: convolutional neural networks, U-Nets, vision transformers, and vision state space models. In doing so, we establish criteria for determining optimal conditions under which each model excels, thereby offering practical guidelines for researchers and practitioners in the field.
Although recent years have witnessed significant advancements in medical image segmentation, the pervasive issue of domain shift among medical images from diverse centres hinders the effective deployment of pre-trained models. Many Test-time Adaptation (TTA) methods have been proposed to address this issue by fine-tuning pre-trained models with test data during inference. These methods, however, often suffer from less-satisfactory optimization due to suboptimal optimization direction (dictated by the gradient) and fixed step-size (predicated on the learning rate). In this paper, we propose the Gradient alignment-based Test-time adaptation (GraTa) method to improve both the gradient direction and learning rate in the optimization procedure. Unlike conventional TTA methods, which primarily optimize the pseudo gradient derived from a self-supervised objective, our method incorporates an auxiliary gradient with the pseudo one to facilitate gradient alignment. Such gradient alignment enables the model to excavate the similarities between different gradients and correct the gradient direction to approximate the empirical gradient related to the current segmentation task. Additionally, we design a dynamic learning rate based on the cosine similarity between the pseudo and auxiliary gradients, thereby empowering the adaptive fine-tuning of pre-trained models on diverse test data. Extensive experiments establish the effectiveness of the proposed gradient alignment and dynamic learning rate and substantiate the superiority of our GraTa method over other state-of-the-art TTA methods on a benchmark medical image segmentation task. The code and weights of pre-trained source models are available at https://github.com/Chen-Ziyang/GraTa.
Multimodal learning leverages complementary information derived from different modalities, thereby enhancing performance in medical image segmentation. However, prevailing multimodal learning methods heavily rely on extensive well-annotated data from various modalities to achieve accurate segmentation performance. This dependence often poses a challenge in clinical settings due to limited availability of such data. Moreover, the inherent anatomical misalignment between different imaging modalities further complicates the endeavor to enhance segmentation performance. To address this problem, we propose a novel semi-supervised multimodal segmentation framework that is robust to scarce labeled data and misaligned modalities. Our framework employs a novel cross modality collaboration strategy to distill modality-independent knowledge, which is inherently associated with each modality, and integrates this information into a unified fusion layer for feature amalgamation. With a channel-wise semantic consistency loss, our framework ensures alignment of modality-independent information from a feature-wise perspective across modalities, thereby fortifying it against misalignments in multimodal scenarios. Furthermore, our framework effectively integrates contrastive consistent learning to regulate anatomical structures, facilitating anatomical-wise prediction alignment on unlabeled data in semi-supervised segmentation tasks. Our method achieves competitive performance compared to other multimodal methods across three tasks: cardiac, abdominal multi-organ, and thyroid-associated orbitopathy segmentations. It also demonstrates outstanding robustness in scenarios involving scarce labeled data and misaligned modalities.
Beyond the Transformer, it is important to explore how to exploit the capacity of the MetaFormer, an architecture that is fundamental to the performance improvements of the Transformer. Previous studies have exploited it only for the backbone network. Unlike previous studies, we explore the capacity of the Metaformer architecture more extensively in the semantic segmentation task. We propose a powerful semantic segmentation network, MetaSeg, which leverages the Metaformer architecture from the backbone to the decoder. Our MetaSeg shows that the MetaFormer architecture plays a significant role in capturing the useful contexts for the decoder as well as for the backbone. In addition, recent segmentation methods have shown that using a CNN-based backbone for extracting the spatial information and a decoder for extracting the global information is more effective than using a transformer-based backbone with a CNN-based decoder. This motivates us to adopt the CNN-based backbone using the MetaFormer block and design our MetaFormer-based decoder, which consists of a novel self-attention module to capture the global contexts. To consider both the global contexts extraction and the computational efficiency of the self-attention for semantic segmentation, we propose a Channel Reduction Attention (CRA) module that reduces the channel dimension of the query and key into the one dimension. In this way, our proposed MetaSeg outperforms the previous state-of-the-art methods with more efficient computational costs on popular semantic segmentation and a medical image segmentation benchmark, including ADE20K, Cityscapes, COCO-stuff, and Synapse. The code is available at https://github.com/hyunwoo137/MetaSeg.
Referring segmentation aims to segment a target object related to a natural language expression. Key challenges of this task are understanding the meaning of complex and ambiguous language expressions and determining the relevant regions in the image with multiple objects by referring to the expression. Recent models have focused on the early fusion with the language features at the intermediate stage of the vision encoder, but these approaches have a limitation that the language features cannot refer to the visual information. To address this issue, this paper proposes a novel architecture, Cross-aware early fusion with stage-divided Vision and Language Transformer encoders (CrossVLT), which allows both language and vision encoders to perform the early fusion for improving the ability of the cross-modal context modeling. Unlike previous methods, our method enables the vision and language features to refer to each other's information at each stage to mutually enhance the robustness of both encoders. Furthermore, unlike the conventional scheme that relies solely on the high-level features for the cross-modal alignment, we introduce a feature-based alignment scheme that enables the low-level to high-level features of the vision and language encoders to engage in the cross-modal alignment. By aligning the intermediate cross-modal features in all encoder stages, this scheme leads to effective cross-modal fusion. In this way, the proposed approach is simple but effective for referring image segmentation, and it outperforms the previous state-of-the-art methods on three public benchmarks.
Fully supervised deep learning (DL) models for surgical video segmentation have been shown to struggle with non-adversarial, real-world corruptions of image quality including smoke, bleeding, and low illumination. Foundation models for image segmentation, such as the segment anything model (SAM) that focuses on interactive prompt-based segmentation, move away from semantic classes and thus can be trained on larger and more diverse data, which offers outstanding zero-shot generalization with appropriate user prompts. Recently, building upon this success, SAM-2 has been proposed to further extend the zero-shot interactive segmentation capabilities from independent frame-by-frame to video segmentation. In this paper, we present a first experimental study evaluating SAM-2's performance on surgical video data. Leveraging the SegSTRONG-C MICCAI EndoVIS 2024 sub-challenge dataset, we assess SAM-2's effectiveness on uncorrupted endoscopic sequences and evaluate its non-adversarial robustness on videos with corrupted image quality simulating smoke, bleeding, and low brightness conditions under various prompt strategies. Our experiments demonstrate that SAM-2, in zero-shot manner, can achieve competitive or even superior performance compared to fully-supervised deep learning models on surgical video data, including under non-adversarial corruptions of image quality. Additionally, SAM-2 consistently outperforms the original SAM and its medical variants across all conditions. Finally, frame-sparse prompting can consistently outperform frame-wise prompting for SAM-2, suggesting that allowing SAM-2 to leverage its temporal modeling capabilities leads to more coherent and accurate segmentation compared to frequent prompting.
This paper provides insights on the effectiveness of the zero shot, prompt-based Segment Anything Model (SAM) and its updated versions, SAM 2 and SAM 2.1, along with the non-promptable conventional neural network (CNN), for segmenting solar panels in RGB aerial remote sensing imagery. The study evaluates these models across diverse lighting conditions, spatial resolutions, and prompt strategies. SAM 2 showed slight improvements over SAM, while SAM 2.1 demonstrated notable improvements, particularly in sub-optimal lighting and low resolution conditions. SAM models, when prompted by user-defined boxes, outperformed CNN in all scenarios; in particular, user-box prompts were found crucial for achieving reasonable performance in low resolution data. Additionally, under high resolution, YOLOv9 automatic prompting outperformed user-points prompting by providing reliable prompts to SAM. Under low resolution, SAM 2.1 prompted by user points showed similar performance to SAM 2.1 prompted by YOLOv9, highlighting its zero shot improvements with a single click. In high resolution with optimal lighting imagery, Eff-UNet outperformed SAMs prompted by YOLOv9, while under sub-optimal lighting conditions, Eff-UNet, and SAM 2.1 prompted by YOLOv9, had similar performance. However, SAM is more resource-intensive, and despite improved inference time of SAM 2.1, Eff-UNet is more suitable for automatic segmentation in high resolution data. This research details strengths and limitations of each model and outlines the robustness of user-prompted image segmentation models.
Medical image segmentation has been traditionally approached by training or fine-tuning the entire model to cater to any new modality or dataset. However, this approach often requires tuning a large number of parameters during training. With the introduction of the Segment Anything Model (SAM) for prompted segmentation of natural images, many efforts have been made towards adapting it efficiently for medical imaging, thus reducing the training time and resources. However, these methods still require expert annotations for every image in the form of point prompts or bounding box prompts during training and inference, making it tedious to employ them in practice. In this paper, we propose an adaptation technique, called S-SAM, that only trains parameters equal to 0.4% of SAM's parameters and at the same time uses simply the label names as prompts for producing precise masks. This not only makes tuning SAM more efficient than the existing adaptation methods but also removes the burden of providing expert prompts. We call this modified version S-SAM and evaluate it on five different modalities including endoscopic images, x-ray, ultrasound, CT, and histology images. Our experiments show that S-SAM outperforms state-of-the-art methods as well as existing SAM adaptation methods while tuning a significantly less number of parameters. We release the code for S-SAM at https://github.com/JayParanjape/SVDSAM.
With the advancement in image editing tools, manipulating digital images has become alarmingly easy. Inpainting, which is used to remove objects or fill in parts of an image, serves as a powerful tool for both image restoration and forgery. This paper introduces a novel approach for detecting image inpainting forgeries by combining DT-CWT with Hierarchical Feature segmentation and with noise inconsistency analysis. The DT-CWT offers several advantages for this task, including inherent shift-invariance, which makes it robust to minor manipulations during the inpainting process, and directional selectivity, which helps capture subtle artifacts introduced by inpainting in specific frequency bands and orientations. By first applying color image segmentation and then analyzing for each segment, noise inconsistency obtained via DT-CW we can identify patterns indicative of inpainting forgeries. The proposed method is evaluated on a benchmark dataset created for this purpose and is compared with existing forgery detection techniques. Our approach demonstrates superior results compared with SOTA in detecting inpainted images.
Medical image segmentation is one of the domains where sufficient annotated data is not available. This necessitates the application of low-data frameworks like few-shot learning. Contemporary prototype-based frameworks often do not account for the variation in features within the support and query images, giving rise to a large variance in prototype alignment. In this work, we adopt a prototype-based self-supervised one-way one-shot learning framework using pseudo-labels generated from superpixels to learn the semantic segmentation task itself. We use a correlation-based probability score to generate a dynamic prototype for each query pixel from the bag of prototypes obtained from the support feature map. This weighting scheme helps to give a higher weightage to contextually related prototypes. We also propose a quadrant masking strategy in the downstream segmentation task by utilizing prior domain information to discard unwanted false positives. We present extensive experimentations and evaluations on abdominal CT and MR datasets to show that the proposed simple but potent framework performs at par with the state-of-the-art methods.
The scarcity and complexity of voxel-level annotations in 3D medical imaging present significant challenges, particularly due to the domain gap between labeled datasets from well-resourced centers and unlabeled datasets from less-resourced centers. This disparity affects the fairness of artificial intelligence algorithms in healthcare. We introduce Diffuse-UDA, a novel method leveraging diffusion models to tackle Unsupervised Domain Adaptation (UDA) in medical image segmentation. Diffuse-UDA generates high-quality image-mask pairs with target domain characteristics and various structures, thereby enhancing UDA tasks. Initially, pseudo labels for target domain samples are generated. Subsequently, a specially tailored diffusion model, incorporating deformable augmentations, is trained on image-label or image-pseudo-label pairs from both domains. Finally, source domain labels guide the diffusion model to generate image-label pairs for the target domain. Comprehensive evaluations on several benchmarks demonstrate that Diffuse-UDA outperforms leading UDA and semi-supervised strategies, achieving performance close to or even surpassing the theoretical upper bound of models trained directly on target domain data. Diffuse-UDA offers a pathway to advance the development and deployment of AI systems in medical imaging, addressing disparities between healthcare environments. This approach enables the exploration of innovative AI-driven diagnostic tools, improves outcomes, saves time, and reduces human error.