In Diffusion Tensor Imaging (DTI) or High Angular Resolution Diffusion Imaging (HARDI), a tensor field or a spherical function field (e.g., an orientation distribution function field), can be estimated from measured diffusion weighted images. In this paper, inspired by the microscopic theoretical treatment of phases in liquid crystals, we introduce a novel mathematical framework, called Director Field Analysis (DFA), to study local geometric structural information of white matter based on the reconstructed tensor field or spherical function field: 1) We propose a set of mathematical tools to process general director data, which consists of dyadic tensors that have orientations but no direction. 2) We propose Orientational Order (OO) and Orientational Dispersion (OD) indices to describe the degree of alignment and dispersion of a spherical function in a single voxel or in a region, respectively; 3) We also show how to construct a local orthogonal coordinate frame in each voxel exhibiting anisotropic diffusion; 4) Finally, we define three indices to describe three types of orientational distortion (splay, bend, and twist) in a local spatial neighborhood, and a total distortion index to describe distortions of all three types. To our knowledge, this is the first work to quantitatively describe orientational distortion (splay, bend, and twist) in general spherical function fields from DTI or HARDI data. The proposed DFA and its related mathematical tools can be used to process not only diffusion MRI data but also general director field data, and the proposed scalar indices are useful for detecting local geometric changes of white matter for voxel-based or tract-based analysis in both DTI and HARDI acquisitions. The related codes and a tutorial for DFA will be released in DMRITool.
We present a method to discover differences between populations with respect to the spatial coherence of their oriented white matter microstructure in arbitrarily shaped white matter regions. This method is applied to diffusion MRI scans of a subset of the Human Connectome Project dataset: 57 pairs of monozygotic and 52 pairs of dizygotic twins. After controlling for morphological similarity between twins, we identify 3.7% of all white matter as being associated with genetic similarity (35.1k voxels, $p < 10^{-4}$, false discovery rate 1.5%), 75% of which spatially clusters into twenty-two contiguous white matter regions. Furthermore, we show that the orientation similarity within these regions generalizes to a subset of 47 pairs of non-twin siblings, and show that these siblings are on average as similar as dizygotic twins. The regions are located in deep white matter including the superior longitudinal fasciculus, the optic radiations, the middle cerebellar peduncle, the corticospinal tract, and within the anterior temporal lobe, as well as the cerebellum, brain stem, and amygdalae. These results extend previous work using undirected fractional anisotrophy for measuring putative heritable influences in white matter. Our multidirectional extension better accounts for crossing fiber connections within voxels. This bottom up approach has at its basis a novel measurement of coherence within neighboring voxel dyads between subjects, and avoids some of the fundamental ambiguities encountered with tractographic approaches to white matter analysis that estimate global connectivity.
Mild traumatic brain injury is a growing public health problem with an estimated incidence of over 1.7 million people annually in US. Diagnosis is based on clinical history and symptoms, and accurate, concrete measures of injury are lacking. This work aims to directly use diffusion MR images obtained within one month of trauma to detect injury, by incorporating deep learning techniques. To overcome the challenge due to limited training data, we describe each brain region using the bag of word representation, which specifies the distribution of representative patch patterns. We apply a convolutional auto-encoder to learn the patch-level features, from overlapping image patches extracted from the MR images, to learn features from diffusion MR images of brain using an unsupervised approach. Our experimental results show that the bag of word representation using patch level features learnt by the auto encoder provides similar performance as that using the raw patch patterns, both significantly outperform earlier work relying on the mean values of MR metrics in selected brain regions.
Diffusion MRI (dMRI) provides the ability to reconstruct neuronal fibers in the brain, $\textit{in vivo}$, by measuring water diffusion along angular gradient directions in q-space. High angular resolution diffusion imaging (HARDI) can produce better estimates of fiber orientation than the popularly used diffusion tensor imaging, but the high number of samples needed to estimate diffusivity requires longer patient scan times. To accelerate dMRI, compressed sensing (CS) has been utilized by exploiting a sparse dictionary representation of the data, discovered through sparse coding. The sparser the representation, the fewer samples are needed to reconstruct a high resolution signal with limited information loss, and so an important area of research has focused on finding the sparsest possible representation of dMRI. Current reconstruction methods however, rely on an angular representation $\textit{per voxel}$ with added spatial regularization, and so, for non-zero signals, one is required to have at least one non-zero coefficient per voxel. This means that the global level of sparsity must be greater than the number of voxels. In contrast, we propose a joint spatial-angular representation of dMRI that will allow us to achieve levels of global sparsity that are below the number of voxels. A major challenge, however, is the computational complexity of solving a global sparse coding problem over large-scale dMRI. In this work, we present novel adaptations of popular sparse coding algorithms that become better suited for solving large-scale problems by exploiting spatial-angular separability. Our experiments show that our method achieves significantly sparser representations of HARDI than is possible by the state of the art.
Knowledge of the noise distribution in magnitude diffusion MRI images is the centerpiece to quantify uncertainties arising from the acquisition process. The use of parallel imaging methods, the number of receiver coils and imaging filters applied by the scanner, amongst other factors, dictate the resulting signal distribution. Accurate estimation beyond textbook Rician or noncentral chi distributions often requires information about the acquisition process (e.g. coils sensitivity maps or reconstruction coefficients), which is not usually available. We introduce a new method where a change of variable naturally gives rise to a particular form of the gamma distribution for background signals. The first moments and maximum likelihood estimators of this gamma distribution explicitly depend on the number of coils, making it possible to estimate all unknown parameters using only the magnitude data. A rejection step is used to make the method automatic and robust to artifacts. Experiments on synthetic datasets show that the proposed method can reliably estimate both the degrees of freedom and the standard deviation. The worst case errors range from below 2% (spatially uniform noise) to approximately 10% (spatially variable noise). Repeated acquisitions of in vivo datasets show that the estimated parameters are stable and have lower variances than compared methods.
In machine learning, novelty detection is the task of identifying novel unseen data. During training, only samples from the normal class are available. Test samples are classified as normal or abnormal by assignment of a novelty score. Here we propose novelty detection methods based on training variational autoencoders (VAEs) on normal data. Since abnormal samples are not used during training, we define novelty metrics based on the (partially complementary) assumptions that the VAE is less capable of reconstructing abnormal samples well; that abnormal samples more strongly violate the VAE regularizer; and that abnormal samples differ from normal samples not only in input-feature space, but also in the VAE latent space and VAE output. These approaches, combined with various possibilities of using (e.g. sampling) the probabilistic VAE to obtain scalar novelty scores, yield a large family of methods. We apply these methods to magnetic resonance imaging, namely to the detection of diffusion-space (q-space) abnormalities in diffusion MRI scans of multiple sclerosis patients, i.e. to detect multiple sclerosis lesions without using any lesion labels for training. Many of our methods outperform previously proposed q-space novelty detection methods. We also evaluate the proposed methods on the MNIST handwritten digits dataset and show that many of them are able to outperform the state of the art.
In the present work, we use information theory to understand the empirical convergence rate of tractography, a widely-used approach to reconstruct anatomical fiber pathways in the living brain. Based on diffusion MRI data, tractography is the starting point for many methods to study brain connectivity. Of the available methods to perform tractography, most reconstruct a finite set of streamlines, or 3D curves, representing probable connections between anatomical regions, yet relatively little is known about how the sampling of this set of streamlines affects downstream results, and how exhaustive the sampling should be. Here we provide a method to measure the information theoretic surprise (self-cross entropy) for tract sampling schema. We then empirically assess four streamline methods. We demonstrate that the relative information gain is very low after a moderate number of streamlines have been generated for each tested method. The results give rise to several guidelines for optimal sampling in brain connectivity analyses.
While the major white matter tracts are of great interest to numerous studies in neuroscience and medicine, their manual dissection in larger cohorts from diffusion MRI tractograms is time-consuming, requires expert knowledge and is hard to reproduce. Tract orientation mapping (TOM) is a novel concept that facilitates bundle-specific tractography based on a learned mapping from the original fiber orientation distribution function (fODF) peaks to a list of tract orientation maps (also abbr. TOM). Each TOM represents one of the known tracts with each voxel containing no more than one orientation vector. TOMs can act as a prior or even as direct input for tractography. We use an encoder-decoder fully-convolutional neural network architecture to learn the required mapping. In comparison to previous concepts for the reconstruction of specific bundles, the presented one avoids various cumbersome processing steps like whole brain tractography, atlas registration or clustering. We compare it to four state of the art bundle recognition methods on 20 different bundles in a total of 105 subjects from the Human Connectome Project. Results are anatomically convincing even for difficult tracts, while reaching low angular errors, unprecedented runtimes and top accuracy values (Dice). Our code and our data are openly available.
생애 전반에 걸친 인지 및 뇌 질환에 중요한 뇌 영역인 천부 백질(SWM, superficial white matter)에는 풍부한 단거리 연합 섬유가 포함되어 있으나, 짧은 궤적과 변동성이 큰 대뇌 피질 주름으로 인해 개체 간 대응이 어려워 그 구조가 완전히 규명되지 않았습니다. 해부학적으로 상응하는 연결은 개체 간에 공간적 위치가 다를 수 있으므로 기하학적 근접성만으로는 적절히 정의되지 않을 수 있습니다. 본 연구에서는 초고해상도 확산 MRI로부터 재구성된 단거리 천부 백질(SWM) 신경로(streamline)를 집단 수준의 클러스터로 체계화하기 위한 비전-언어(vision-language) 모델(VLM)인 FiberGeoText(FGT)를 소개합니다. FGT는 각 신경로의 세 가지 상호보완적 특성인 3차원 궤적, 피질 해부학적 컨텍스트, 형태를 공동으로 표현합니다. 여러 구획화(parcellation) 체계의 피질 종단점 정보는 텍스트로 표현되고 사전학습된 대규모 언어 모델(LLM)을 사용하여 인코딩되므로, 이종의 해부학적 기술이 공통의 연속적 표현에 기여할 수 있습니다. 밀리미터 미만인 0.76mm 확산 MRI 데이터를 통해 FGT를 평가했습니다. 최신(SOTA) 방법들과 비교했을 때, FGT는 훨씬 더 높은 피질 구획 일관성, 클러스터 내 형태 일관성, 클러스터 크기 일관성, 피험자 간 대응성을 달성했습니다. 또한 학습된 모델은 학습된 5,000개 클러스터 중 평균 96.7%를 복구하며 미확인 피험자에 대해서도 우수한 일반화 성능을 보였고, 학습 데이터와 테스트 데이터 간의 클러스터 구조 일관성도 높았습니다. 이러한 결과는 VLM 모델을 통해 멀티모달 딥 임베딩(embedding)을 학습함으로써 기하학적, 해부학적, 형태 정보를 통합하는 것이 개체 간 해부학적 변동성에도 불구하고 집단 수준에서 일관된 SWM 구조를 강건하게 학습할 수 있음을 입증합니다.
확산강조영상(DWI)은 특히 시간 효율적인 프로토콜과 움직임이 발생하기 쉬운 피험자 집단에서 피험자의 움직임에 매우 취약합니다. 슬라이스-볼륨 정합(SVR)이 슬라이스 간 및 스택 간 불일치를 완화할 수 있지만, 확산 MRI는 확산 방향에 따른 대조도와 수십 개의 측정값을 공통 기준 좌표계 내에 정렬해야 하는 요구사항으로 인해 추가적인 복잡성을 유발하며, 실질적으로 4D 정합 문제를 낳습니다. 기존 접근 방식은 주로 순차적 모델링이나 쌍별 유사도에 의존하며, 희소한 그래디언트 샘플링이나 심한 움직임 환경에서 종종 성능이 저하됩니다. 본 연구에서는 DWI의 4D SVR 정합을 위한 q-공간 인지 그래프 기반 프레임워크인 GraphSVR을 소개합니다. GraphSVR은 획득 구조화된 그래프에서 슬라이스 그룹을 노드로 표현하며, 에지는 시간적 근접성, 공간적 슬라이스 기하구조, 확산 인코딩 관계를 인코딩합니다. 그래프 신경망은 전역적으로 일관된 스택 단위 강체 운동을 예측하며, 쌍을 이루는 정답 움직임 없이 해부학적 참조 영상만을 사용하여 자기지도, 제로샷(zero-shot) 방식으로 최적화됩니다. 제어 가능한 움직임 심각도와 그래디언트 희소성을 갖는 실제 획득 기반의 사실적인 재조합 시뮬레이션 및 완전 합성 확산 시뮬레이션 모두를 사용하여 GraphSVR을 평가합니다. 성능은 알려진 정답 변환 대비 그리드 오차(mm) 및 회전 오차를 사용하여 정량화됩니다. 심각한 움직임 하에서 GraphSVR은 표준 DWI 움직임 보정 방법인 FSL eddy에 비해 그리드 오차와 회전 오차를 73% 감소시키며, 가장 큰 개선 효과는 희소 방향 영역에서 관찰됩니다. 이러한 결과는 그래프 기반 추론을 통해 획득 구조를 명시적으로 모델링하는 것이 4D DWI 움직임 추정에서 견고성과 전역적 일관성을 향상시킨다는 점을 보여줍니다. 코드는 https://github.com/nogakertes/GraphSVR.git 에서 이용할 수 있습니다.
XGBoost, SHAP, 재귀적 특징 제거(RFE)를 결합한 설명 가능한 AI(XAI) 프레임워크를 활용해 신경돌기 교환 영상(NEXI) 확산 MRI 프로토콜을 27분에서 14분으로 단축하는 최적 8개 특징 부분집합을 식별했으며, 데이터 기반 선택이 이론적 최적값인 크라메르-라오 하한(CRLB)에 수렴함을 검증했다. 이 모델 무관(model-agnostic) 최적화 프레임워크는 복잡한 야코비안 유도 없이 금표준 수준의 최적화를 달성하여 기존 휴리스틱 대비 우수한 생체 내 강건성을 보이며, 미래 초고 그래디언트 시스템 및 임상 스캐너에 적용 가능한 회백질 미세구조 정량화 방법을 확립한다.
확산 MRI의 NODDI 맵(NDI, ODI, FWF)에서 고유·중복·시너지 정보를 자기지도 방식으로 분리하는 Self-supervised Partial Information Decomposition(SPID)과 전문가 혼합(MoE) 아키텍처를 결합한 뇌 미세구조 최초의 파운데이션 모델 BrainFIBRE를 제안한다. UK Biobank 55,592명 데이터로 사전학습한 이 모델은 나이·성별·뇌혈관 질환·인지 기능 예측 등 다양한 하류 과제에서 코카서스계 및 아시아계 코호트 모두에 걸쳐 최고 성능을 달성하며 신경생물학적으로 해석 가능한 표현을 제공한다.
ex vivo dMRI 트랙토그래피를 생성적 사전(generative prior)으로 활용해 마카크 트레이서 조직학의 섬유 다발 분할을 위한 합성 데이터 증강 프레임워크를 제안하며, 합성 이미지 패치와 실제 데이터를 혼합해 2D U-Net을 학습시킨다. 이 접근법은 수동 주석 데이터를 3배 적게 사용하면서도 최신 기술 수준의 성능을 달성하고, 다양한 뇌와 섬유 다발 밀도에 대한 일반화 성능을 개선한다.