PyTorchKR Papers

최신 논문

총 12편
태그·기간 등 상세 필터

카테고리 탐색

로그인 후 이 태그 구독

arXiv:2503.19329공식 코드 · Papers with Code

Wavelet-based Global-Local Interaction Network with Cross-Attention for Multi-View Diabetic Retinopathy Detection

Multi-view diabetic retinopathy (DR) detection has recently emerged as a promising method to address the issue of incomplete lesions faced by single-view DR. However, it is still challenging due to the variable sizes and scattered locations of lesions. Furthermore, existing multi-view DR methods typically merge multiple views without considering the correlations and redundancies of lesion information across them. Therefore, we propose a novel method to overcome the challenges of difficult lesion information learning and inadequate multi-view fusion. Specifically, we introduce a two-branch network to obtain both local lesion features and their global dependencies. The high-frequency component of the wavelet transform is used to exploit lesion edge information, which is then enhanced by global semantic to facilitate difficult lesion learning. Additionally, we present a cross-view fusion module to improve multi-view fusion and reduce redundancy. Experimental results on large public datasets demonstrate the effectiveness of our method. The code is open sourced on https://github.com/HuYongting/WGLIN.

arXiv:2405.00417공식 코드 · Papers with Code

Conformal Risk Control for Ordinal Classification

As a natural extension to the standard conformal prediction method, several conformal risk control methods have been recently developed and applied to various learning problems. In this work, we seek to control the conformal risk in expectation for ordinal classification tasks, which have broad applications to many real problems. For this purpose, we firstly formulated the ordinal classification task in the conformal risk control framework, and provided theoretic risk bounds of the risk control method. Then we proposed two types of loss functions specially designed for ordinal classification tasks, and developed corresponding algorithms to determine the prediction set for each case to control their risks at a desired level. We demonstrated the effectiveness of our proposed methods, and analyzed the difference between the two types of risks on three different datasets, including a simulated dataset, the UTKFace dataset and the diabetic retinopathy detection dataset.

arXiv:2211.03148공식 코드 · Papers with Code

UATTA-ENS: Uncertainty Aware Test Time Augmented Ensemble for PIRC Diabetic Retinopathy Detection

Deep Ensemble Convolutional Neural Networks has become a methodology of choice for analyzing medical images with a diagnostic performance comparable to a physician, including the diagnosis of Diabetic Retinopathy. However, commonly used techniques are deterministic and are therefore unable to provide any estimate of predictive uncertainty. Quantifying model uncertainty is crucial for reducing the risk of misdiagnosis. A reliable architecture should be well-calibrated to avoid over-confident predictions. To address this, we propose a UATTA-ENS: Uncertainty-Aware Test-Time Augmented Ensemble Technique for 5 Class PIRC Diabetic Retinopathy Classification to produce reliable and well-calibrated predictions.

arXiv:2207.04345공식 코드 · Papers with Code

Segmentation of Blood Vessels, Optic Disc Localization, Detection of Exudates and Diabetic Retinopathy Diagnosis from Digital Fundus Images

Diabetic Retinopathy (DR) is a complication of long-standing, unchecked diabetes and one of the leading causes of blindness in the world. This paper focuses on improved and robust methods to extract some of the features of DR, viz. Blood Vessels and Exudates. Blood vessels are segmented using multiple morphological and thresholding operations. For the segmentation of exudates, k-means clustering and contour detection on the original images are used. Extensive noise reduction is performed to remove false positives from the vessel segmentation algorithm's results. The localization of Optic Disc using k-means clustering and template matching is also performed. Lastly, this paper presents a Deep Convolutional Neural Network (DCNN) model with 14 Convolutional Layers and 2 Fully Connected Layers, for the automatic, binary diagnosis of DR. The vessel segmentation, optic disc localization and DCNN achieve accuracies of 95.93%, 98.77% and 75.73% respectively. The source code and pre-trained model are available https://github.com/Sohambasu07/DR_2021

arXiv:2206.07387공식 코드 · Papers with Code

The Manifold Hypothesis for Gradient-Based Explanations

When do gradient-based explanation algorithms provide perceptually-aligned explanations? We propose a criterion: the feature attributions need to be aligned with the tangent space of the data manifold. To provide evidence for this hypothesis, we introduce a framework based on variational autoencoders that allows to estimate and generate image manifolds. Through experiments across a range of different datasets -- MNIST, EMNIST, CIFAR10, X-ray pneumonia and Diabetic Retinopathy detection -- we demonstrate that the more a feature attribution is aligned with the tangent space of the data, the more perceptually-aligned it tends to be. We then show that the attributions provided by popular post-hoc methods such as Integrated Gradients and SmoothGrad are more strongly aligned with the data manifold than the raw gradient. Adversarial training also improves the alignment of model gradients with the data manifold. As a consequence, we suggest that explanation algorithms should actively strive to align their explanations with the data manifold. This is an extended version of a CVPR Workshop paper. Code is available at https://github.com/tml-tuebingen/explanations-manifold.

arXiv:2107.00296공식 코드 · Papers with Code

Explainable Diabetic Retinopathy Detection and Retinal Image Generation

Though deep learning has shown successful performance in classifying the label and severity stage of certain diseases, most of them give few explanations on how to make predictions. Inspired by Koch's Postulates, the foundation in evidence-based medicine (EBM) to identify the pathogen, we propose to exploit the interpretability of deep learning application in medical diagnosis. By determining and isolating the neuron activation patterns on which diabetic retinopathy (DR) detector relies to make decisions, we demonstrate the direct relation between the isolated neuron activation and lesions for a pathological explanation. To be specific, we first define novel pathological descriptors using activated neurons of the DR detector to encode both spatial and appearance information of lesions. Then, to visualize the symptom encoded in the descriptor, we propose Patho-GAN, a new network to synthesize medically plausible retinal images. By manipulating these descriptors, we could even arbitrarily control the position, quantity, and categories of generated lesions. We also show that our synthesized images carry the symptoms directly related to diabetic retinopathy diagnosis. Our generated images are both qualitatively and quantitatively superior to the ones by previous methods. Besides, compared to existing methods that take hours to generate an image, our second level speed endows the potential to be an effective solution for data augmentation.

arXiv:2101.03581공식 코드 · Papers with Code

Curvature-based Feature Selection with Application in Classifying Electronic Health Records

Disruptive technologies provides unparalleled opportunities to contribute to the identifications of many aspects in pervasive healthcare, from the adoption of the Internet of Things through to Machine Learning (ML) techniques. As a powerful tool, ML has been widely applied in patient-centric healthcare solutions. To further improve the quality of patient care, Electronic Health Records (EHRs) are commonly adopted in healthcare facilities for analysis. It is a crucial task to apply AI and ML to analyse those EHRs for prediction and diagnostics due to their highly unstructured, unbalanced, incomplete, and high-dimensional nature. Dimensionality reduction is a common data preprocessing technique to cope with high-dimensional EHR data, which aims to reduce the number of features of EHR representation while improving the performance of the subsequent data analysis, e.g. classification. In this work, an efficient filter-based feature selection method, namely Curvature-based Feature Selection (CFS), is presented. The proposed CFS applied the concept of Menger Curvature to rank the weights of all features in the given data set. The performance of the proposed CFS has been evaluated in four well-known EHR data sets, including Cervical Cancer Risk Factors (CCRFDS), Breast Cancer Coimbra (BCCDS), Breast Tissue (BTDS), and Diabetic Retinopathy Debrecen (DRDDS). The experimental results show that the proposed CFS achieved state-of-the-art performance on the above data sets against conventional PCA and other most recent approaches. The source code of the proposed approach is publicly available at https://github.com/zhemingzuo/CFS.

arXiv:2006.03829공식 코드 · Papers with Code

3D Self-Supervised Methods for Medical Imaging

Self-supervised learning methods have witnessed a recent surge of interest after proving successful in multiple application fields. In this work, we leverage these techniques, and we propose 3D versions for five different self-supervised methods, in the form of proxy tasks. Our methods facilitate neural network feature learning from unlabeled 3D images, aiming to reduce the required cost for expert annotation. The developed algorithms are 3D Contrastive Predictive Coding, 3D Rotation prediction, 3D Jigsaw puzzles, Relative 3D patch location, and 3D Exemplar networks. Our experiments show that pretraining models with our 3D tasks yields more powerful semantic representations, and enables solving downstream tasks more accurately and efficiently, compared to training the models from scratch and to pretraining them on 2D slices. We demonstrate the effectiveness of our methods on three downstream tasks from the medical imaging domain: i) Brain Tumor Segmentation from 3D MRI, ii) Pancreas Tumor Segmentation from 3D CT, and iii) Diabetic Retinopathy Detection from 2D Fundus images. In each task, we assess the gains in data-efficiency, performance, and speed of convergence. Interestingly, we also find gains when transferring the learned representations, by our methods, from a large unlabeled 3D corpus to a small downstream-specific dataset. We achieve results competitive to state-of-the-art solutions at a fraction of the computational expense. We publish our implementations for the developed algorithms (both 3D and 2D versions) as an open-source library, in an effort to allow other researchers to apply and extend our methods on their datasets.

arXiv:1908.10508공식 코드 · Papers with Code

O-MedAL: Online Active Deep Learning for Medical Image Analysis

Active Learning methods create an optimized labeled training set from unlabeled data. We introduce a novel Online Active Deep Learning method for Medical Image Analysis. We extend our MedAL active learning framework to present new results in this paper. Our novel sampling method queries the unlabeled examples that maximize the average distance to all training set examples. Our online method enhances performance of its underlying baseline deep network. These novelties contribute significant performance improvements, including improving the model's underlying deep network accuracy by 6.30%, using only 25% of the labeled dataset to achieve baseline accuracy, reducing backpropagated images during training by as much as 67%, and demonstrating robustness to class imbalance in binary and multi-class tasks.

arXiv:1901.06852공식 코드 · Papers with Code

Maximum Likelihood with Bias-Corrected Calibration is Hard-To-Beat at Label Shift Adaptation

Label shift refers to the phenomenon where the prior class probability p(y) changes between the training and test distributions, while the conditional probability p(x|y) stays fixed. Label shift arises in settings like medical diagnosis, where a classifier trained to predict disease given symptoms must be adapted to scenarios where the baseline prevalence of the disease is different. Given estimates of p(y|x) from a predictive model, Saerens et al. proposed an efficient maximum likelihood algorithm to correct for label shift that does not require model retraining, but a limiting assumption of this algorithm is that p(y|x) is calibrated, which is not true of modern neural networks. Recently, Black Box Shift Learning (BBSL) and Regularized Learning under Label Shifts (RLLS) have emerged as state-of-the-art techniques to cope with label shift when a classifier does not output calibrated probabilities, but both methods require model retraining with importance weights and neither has been benchmarked against maximum likelihood. Here we (1) show that combining maximum likelihood with a type of calibration we call bias-corrected calibration outperforms both BBSL and RLLS across diverse datasets and distribution shifts, (2) prove that the maximum likelihood objective is concave, and (3) introduce a principled strategy for estimating source-domain priors that improves robustness to poor calibration. This work demonstrates that the maximum likelihood with appropriate calibration is a formidable and efficient baseline for label shift adaptation; notebooks reproducing experiments available at https://github.com/kundajelab/labelshiftexperiments

arXiv:1703.10757공식 코드 · Papers with Code

Diabetic Retinopathy Detection via Deep Convolutional Networks for Discriminative Localization and Visual Explanation

We proposed a deep learning method for interpretable diabetic retinopathy (DR) detection. The visual-interpretable feature of the proposed method is achieved by adding the regression activation map (RAM) after the global averaging pooling layer of the convolutional networks (CNN). With RAM, the proposed model can localize the discriminative regions of an retina image to show the specific region of interest in terms of its severity level. We believe this advantage of the proposed deep learning model is highly desired for DR detection because in practice, users are not only interested with high prediction performance, but also keen to understand the insights of DR detection and why the adopted learning model works. In the experiments conducted on a large scale of retina image dataset, we show that the proposed CNN model can achieve high performance on DR detection compared with the state-of-the-art while achieving the merits of providing the RAM to highlight the salient regions of the input image.

arXiv:1803.04337공식 코드 · Papers with Code

Replication study: Development and validation of deep learning algorithm for detection of diabetic retinopathy in retinal fundus photographs

Replication studies are essential for validation of new methods, and are crucial to maintain the high standards of scientific publications, and to use the results in practice. We have attempted to replicate the main method in 'Development and validation of a deep learning algorithm for detection of diabetic retinopathy in retinal fundus photographs' published in JAMA 2016; 316(22). We re-implemented the method since the source code is not available, and we used publicly available data sets. The original study used non-public fundus images from EyePACS and three hospitals in India for training. We used a different EyePACS data set from Kaggle. The original study used the benchmark data set Messidor-2 to evaluate the algorithm's performance. We used the same data set. In the original study, ophthalmologists re-graded all images for diabetic retinopathy, macular edema, and image gradability. There was one diabetic retinopathy grade per image for our data sets, and we assessed image gradability ourselves. Hyper-parameter settings were not described in the original study. But some of these were later published. We were not able to replicate the original study. Our algorithm's area under the receiver operating curve (AUC) of 0.94 on the Kaggle EyePACS test set and 0.80 on Messidor-2 did not come close to the reported AUC of 0.99 in the original study. This may be caused by the use of a single grade per image, different data, or different not described hyper-parameter settings. This study shows the challenges of replicating deep learning, and the need for more replication studies to validate deep learning methods, especially for medical image analysis. Our source code and instructions are available at: https://github.com/mikevoets/jama16-retina-replication