이 이메일 도메인이 관측된 논문 2건

arXiv:2609.20868v1physics.ins-det

Automated Physics-Informed Neural-Networks-Based Calibration of Highly Segmented Silicon Telescopes

Transfer and multi-nucleon transfer reactions are essential tools for probing nuclear structure and reaction dynamics, requiring precise determination of the identity, energy, and emission angles of reaction products. The increasing granularity of modern silicon telescope arrays enhances experimental capabilities but challenges detector calibration, as conventional channel-by-channel approaches become inefficient and difficult to scale. In this work, we present a fully automated, physics-informed calibration framework based on neural networks, specifically designed for highly segmented silicon detector arrays. The method formulates calibration as a global optimization problem, in which detector gains and geometrical corrections are determined simultaneously by minimizing the width of the reconstructed excitation energy under two-body kinematics constraints. The approach relies exclusively on experimental data and well-established physical principles, without requiring explicit modeling of detector response. A distinctive feature is the use of multiple neural network sub-models sharing a common loss function with embedded physics constraints, enabling coherent and self-consistent calibration across all detector channels. This strategy ensures scalability, robustness, and reproducibility, making it particularly suitable for next-generation detector systems with increasing complexity. The performance of the method is demonstrated using experimental data from the Particle-Identification Silicon-Telescope Array (PISTA) in high-resolution fission studies in inverse kinematics. The results show excellent agreement with theoretical kinematics, high-quality particle identification, and a significant improvement in calibration efficiency. The proposed framework provides a general and adaptable solution for the calibration of complex detector systems in modern nuclear physics experiments.

arXiv:2606.29466v1cs.LG

물리적 일관성 제약을 활용한 과학 장비의 자기지도 보정

Self-Supervised Calibration of Scientific Instruments Using Physical Consistency Constraints

과학 계측기 보정(calibration)을 자기지도(self-supervised) 최적화 문제로 재정의하여, 사전 보정 신호나 외부 레이블 없이 원시 측정값에서 검출기 보정 파라미터와 태스크별 예측을 동시에 학습하는 물리 정보 기반 프레임워크를 제안한다. VAMOS++ 자기 분광기에서의 이온 전하 상태 결정 실험을 통해, 원자 질량의 이산적 특성을 활용한 반복적 분수 의사 레이블링(pseudo-labelling)이 정확한 보정과 자동 검출기 상태 모니터링을 동시에 가능하게 함을 입증하였다.